Continuous glucose monitoring with Humalog Mix 25 versus Humalog Mix 50, twice daily: A comparative pilot study -Results from the Jikei-EValuation of insulin Lispro mixture on pharmacodynamics and glycemic VariancE (J-EVOLVE) study
نویسندگان
چکیده
OBJECTIVE To evaluate glycemic variability associated with two different premixed insulin analogue formulations when used in a twice-daily regimen. PATIENTS AND METHODS Subjects comprised type 2 diabetic patients aged 20-79 years, treated with twice daily premixed insulin or insulin analogue formulations. All subjects were hospitalized for 6 days and randomized to receive either Humalog Mix 25 (Mix 25) or Humalog Mix 50 (Mix 50). They were then crossed over to the other arm between day 3 and day 4 of the study. Continuous glucose monitoring (CGM) was performed on all subjects to examine the differences in glycemic variability. RESULTS Eleven type 2 diabetic patients were enrolled. No significant difference was found in 24-hour mean glucose values and their SDs, pre-meal glucose values, increases from pre-meal to peak glucose values, or time to peak glucose levels between either group. However, the mean glucose values observed during 0-8 hrs were significantly lower with Mix 25 compared to Mix 50 (128 vs. 147 mg/dL; p = 0.024). CONCLUSIONS The twice-daily Mix 25 regimen provided superior overnight glycemic control compared to the Mix 50 regimen in Japanese patients with type 2 diabetes. However, both twice-daily regimens with either Mix 25 or Mix 50 provided inadequate post-lunch glycemic control. TRIAL REGISTRATION Current Controlled Trials UMIN000001327.
منابع مشابه
Effectiveness and safety of Humalog Mix 50/50 versus Humalog Mix 75/25 in Chinese patients with type 2 diabetes
Humalog Mix 75/25 insulin analog is widely used in the People's Republic of China to treat type 2 diabetes mellitus, but the Humalog Mix 50/50 analog is not as yet widely used or assessed. The purpose of this 12-week, parallel-group, randomized, treat-to-target study was to evaluate the difference in clinical efficacy, safety, and outcome of treatment between Humalog Mix 50/50 and Humalog Mix 7...
متن کاملComparative efficacy of humalog mix 75/25 with human Insulin
The study is designed to compare the postprandial glucodynamic profile of humalog mix 75/25, a new premixed insulin analogue containing 75% neutral protamine lispro and 25% insulin lispro with that of human insulin 70/30 in patients with type 2 diabetes mellitus. Insulin lispro mix 75/25 is the first available insulin formulation in which both the rapid-acting and basal components are insulin a...
متن کاملThe economic value of a new insulin preparation, Humalog Mix 25. Measured by a willingness-to-pay approach.
OBJECTIVE To measure the economic value of a new insulin formulation consisting of rapid-acting insulin lispro and intermediate-acting neutral protamine lispro in a 25:75 ratio (Humalog Mix 25). DESIGN AND SETTING A cost-benefit analysis using a consumer-based willingness-to-pay (WTP) approach was used. The study sample consisted of 80 Canadian taxpayers randomly selected from Ontario and Que...
متن کاملBioequivalence and comparative pharmacodynamics of insulin lispro 200 U/mL relative to insulin lispro (Humalog®) 100 U/mL
Insulin lispro 200 U/mL (IL200) is a new strength formulation of insulin lispro (Humalog®, IL100), developed as an option for diabetic patients on higher daily mealtime insulin doses. This phase 1, open-label, 2-sequence, 4-period crossover, randomized, 8-hour euglycemic clamp study aimed to demonstrate the bioequivalence of IL200 and IL100 after subcutaneous administration of 20 U (U) to healt...
متن کاملUsing Premixed Biphasic Insulin Analogs Humalog® Mix 25 and Humalog® Mix50 in Basal Bolus Format: Evidence from Research, Clinical Practice and Case Reports
Submit Manuscript | http://medcraveonline.com degludec/Tresiba®) have been proven more safer and efficacious in management of type-1 and type-2 diabetes, as compared to older or traditional insulins (Human Regular and NPH), with better glycemic control (HbA1c reductions) and less or negligible hypoglycemia; these insulin analogs are available as insulin pens and more easy to use. Furthermore, t...
متن کامل