Feasibility study of ultrasound imaging for stereotactic body radiation therapy with active breathing coordinator in pancreatic cancer

نویسندگان

  • Lin Su
  • Iulian Iordachita
  • Yin Zhang
  • Junghoon Lee
  • Sook Kien Ng
  • Juan Jackson
  • Ted Hooker
  • John Wong
  • Joseph M. Herman
  • H. Tutkun Sen
  • Peter Kazanzides
  • Muyinatu A. Lediju Bell
  • Chen Yang
  • Kai Ding
چکیده

PURPOSE Stereotactic body radiation therapy (SBRT) allows for high radiation doses to be delivered to the pancreatic tumors with limited toxicity. Nevertheless, the respiratory motion of the pancreas introduces major uncertainty during SBRT. Ultrasound imaging is a non-ionizing, non-invasive, and real-time technique for intrafraction monitoring. A configuration is not available to place the ultrasound probe during pancreas SBRT for monitoring. METHODS AND MATERIALS An arm-bridge system was designed and built. A CT scan of the bridge-held ultrasound probe was acquired and fused to ten previously treated pancreatic SBRT patient CTs as virtual simulation CTs. Both step-and-shoot intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning were performed on virtual simulation CT. The accuracy of our tracking algorithm was evaluated by programmed motion phantom with simulated breath-hold 3D movement. An IRB-approved volunteer study was also performed to evaluate feasibility of system setup. Three healthy subjects underwent the same patient setup required for pancreas SBRT with active breath control (ABC). 4D ultrasound images were acquired for monitoring. Ten breath-hold cycles were monitored for both phantom and volunteers. For the phantom study, the target motion tracked by ultrasound was compared with motion tracked by the infrared camera. For the volunteer study, the reproducibility of ABC breath-hold was assessed. RESULTS The volunteer study results showed that the arm-bridge system allows placement of an ultrasound probe. The ultrasound monitoring showed less than 2 mm reproducibility of ABC breath-hold in healthy volunteers. The phantom monitoring accuracy is 0.14 ± 0.08 mm, 0.04 ± 0.1 mm, and 0.25 ± 0.09 mm in three directions. On dosimetry part, 100% of virtual simulation plans passed protocol criteria. CONCLUSIONS Our ultrasound system can be potentially used for real-time monitoring during pancreas SBRT without compromising planning quality. The phantom study showed high monitoring accuracy of the system, and the volunteer study showed feasibility of the clinical workflow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Breathing Coordinator Reproducibility of liver position using Active Breathing CoordinatorTM for liver cancer

The purpose of this paper is to describe the reproducibility of liver position using Active Breathing Coordinator in a larger series of patients with more advanced liver cancer, consecutively planned for SBRT delivered in six fractions over two weeks. In this study, repeat megavoltage (MV) verification imaging, real-time beams-eye-view MV movies, conventional kV fluoroscopy, cone beam kV fluoro...

متن کامل

First clinical implementation of audiovisual biofeedback in liver cancer stereotactic body radiation therapy

This case report details a clinical trial's first recruited liver cancer patient who underwent a course of stereotactic body radiation therapy treatment utilising audiovisual biofeedback breathing guidance. Breathing motion results for both abdominal wall motion and tumour motion are included. Patient 1 demonstrated improved breathing motion regularity with audiovisual biofeedback. A training e...

متن کامل

EUS-Guided Pancreatic Diagnosis and Beyond

The therapeutic ability of endoscopic ultrasound has expanded, especially in assisting with radiation planning for image guided radiation techniques such as stereotactic body radiation therapy. Endoscopic ultrasound enables precise placement of fiducial markers into pancreatic cancers to accurately delineate the position of the target lesion as it moves with respiration. The authors summarize t...

متن کامل

Active Breathing Coordinator in adjuvant three-dimensional conformal radiotherapy of early stage breast cancer: a feasibility study.

AIMS To investigate the technical feasibility of utilizing the Active Breathing Coordinator for planning of postoperative three-dimensional conformal radiation therapy in patients with early stage breast cancer undergoing breast conservation therapy. METHODS Patients with early stage breast cancer for whom adjuvant radiotherapy after breast-conserving surgery was planned were consecutively en...

متن کامل

Stereotactic body radiation therapy (SBRT) in pancreatic cancer: is it ready for prime time?

Pancreatic cancer is a devastating disease with few effective treatment modalities. Stereotactic body radiation therapy is a novel technique that takes advantage of the technologic advancements in image guidance and radiation dose delivery to direct ablative doses to tumors with acceptable toxicity that was not previously achievable with conventional techniques. Recent literature contains repor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017