B-scan ultrasonography in the evaluation of retinal detachment.

نویسندگان

  • J V Forrester
  • G R Sutherland
چکیده

The use of B-scan ultrasonography was first reported by Baum and Greenwood (I958), who described their results as equivalent to the first x rays. As they predicted, improvement in equipment and technique has led to increased resolution of ocular structure being obtained by B-scan ultrasonography. The clinical application of the B-scan has been described by Coleman and Jack (I973) and the reliability of diagnosis of retinal detachment placed at I00 per cent. (Coleman, 1972). Previous fears of ocular hazards and difficulties in technique (Ballantyne and Michaelson, 1970) have so far proved groundless. The purpose of this communication is two-fold: (a) To present the results of B-scan examination of the eye, using a standard ultrasonic machine, which has been designed primarily for abdominal and obstetric use and which should be available in most general hospitals; (b) To illustrate the usefulness of B-scan echography as an additional approach to the assessment of retinal detachment as a confirmatory or diagnostic aid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B-scan ultrasonography of ocular abnormalities: a review of 182 dogs

Ultrasonography is the only practical method for obtaining images of the posterior segment of the eye when the light-conducting media are opaque. In this study, 182 dogs with ocular abnormalities presented to the Department of Veterinary Surgery and Radiology from December 2008-August 2010 were included. All the animals were subjected to detailed ophthalmic examination and B-scan ultrasonograph...

متن کامل

Spectral domain optical coherence tomography and B-scan ultrasonography in the evaluation of retinal tears in acute, incomplete posterior vitreous detachment

BACKGROUND The purpose of this study was to evaluate the extension and traction effects of posterior vitreous detachment (PVD) complicated with retinal tears using spectral domain optical coherence tomography (OCT) and B-scan ultrasonography. METHODS Complete ophthalmological examination, B-scan ultrasonography and spectral domain OCT were performed in patients with acute PVD and retinal tear...

متن کامل

Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer

PURPOSE To assess the accuracy of B-scan ultrasound (U/S) in diagnosing cases of acute fundus obscuring vitreous hemorrhage (FOVH) using a standardized scan protocol and dedicated ophthalmic ultrasonographer. METHODS Consecutive patients presenting with acute FOVH of unknown cause, between January 2013 and December 2014, were prospectively recruited. Patients underwent a scan performed by a d...

متن کامل

OUTPATIENT RETINAL DETACHMENT SURGERY: A PRELIMINARY REPORT

Retinal detachment surgery has been considered an inpatient hospital procedure requiring preoperative and postoperative hospitalization. In this pilot study, outpatient retinal detachment surgery was performed on sixteen patients and the results (100% success rate after an average follow-up of 8.3 months) were comparable or better than reported overall success rates for retinal detachment ...

متن کامل

A clinical study of annular cyclitis

PURPOSE To investigate six cases of annular cyclitis. METHODS All patients with impairment of visual acuity underwent complete ophthalmologic examination, color fundus photography, laboratory tests and fluorescein angiography. Indocyanine green (ICG) angiography and B-scan ultrasonography were also performed in three cases in order to diagnose the disease. RESULTS All patients presented a u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 58 8  شماره 

صفحات  -

تاریخ انتشار 1974