Determination of bleb capsule porosity with an experimental glaucoma drainage device and measurement system.

نویسندگان

  • Craig Ross
  • Surinder Singh Pandav
  • Yu Qin Li
  • Dan Q Nguyen
  • Stephen Beirne
  • Gordon G Wallace
  • Tarek Shaarawy
  • Jonathan G Crowston
  • Michael Coote
چکیده

IMPORTANCE Control of intraocular pressure after implantation of a glaucoma drainage device (GDD) depends on the porosity of the capsule that forms around the plate of the GDD. OBJECTIVE To compare capsular porosity after insertion of 2 different GDDs using a novel implant and measurement system. DESIGN, SETTING, AND SUBJECTS We performed an experimental interventional study at an eye research facility in a tertiary eye care center. Testing was performed on 22 adult New Zealand white rabbits that received the experimental GDD or an existing GDD. INTERVENTIONS A new experimental GDD, the Center for Eye Research Australia (CERA) implant, was created using computer-aided design and a 3-dimensional printer. The CERA GDDs were implanted in the eyes of rabbits randomized into 1 of the following 3 groups: with no connection to the anterior chamber (n = 7), with connection to the anterior chamber for 1 week (n = 5), and with connection to the anterior chamber for 4 weeks (n = 5). In a control group (n = 5), a pediatric GDD was implanted without connection to the anterior chamber. We measured the capsular porosity using a pressure-gated picoliter pump at a driving pressure of 12 mm Hg. The animals were killed humanely for histologic study. MAIN OUTCOMES AND MEASURES Porosity of the fibrous capsule around the implant. RESULTS We found no difference in mean (SEM) capsular porosity between the CERA (3.39 [0.76; 95% CI, 1.43-5.48] µL/min) and pediatric (4.52 [0.52; 95% CI, 3.19-5.95] µL/min) GDDs (P = .28, unpaired t test) at 4 weeks without aqueous exposure. Mean (SEM) capsular porosity of CERA GDDs connected to the anterior chamber at 1 week was 2.46 (0.36; 95% CI, 1.55-3.44) µL/min but decreased to 0.67 (0.07; 95% CI, 0.49-0.86) µL/min at 4 weeks (P = .001, unpaired t test). CONCLUSIONS AND RELEVANCE Our experimental method permits direct measurement of capsular porosity of an in situ GDD. In a comparison between an experimental (CERA) and an existing GDD, no differences were identified in capsular porosity or histologic reaction between the implants. These results suggest that the CERA GDD model can be used to test key components of glaucoma surgery and implant design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Porosity of Bleb Capsule declines rapidly with Fluid Challenge

INTRODUCTION The porosity of the fibrous capsule around a glaucoma drainage device (GDD) may be the most important functional attribute. The factors that determine capsular porosity are not well understood. Failed GDD surgeries are usually associated with thick impervious capsules and components of aqueous have been implicated in this process. PURPOSE In this study, we interrogated the effect...

متن کامل

Pirfenidone inhibits fibrosis in foreign body reaction after glaucoma drainage device implantation

BACKGROUND The aim of this study was to investigate the antiscarring effects of pirfenidone on foreign body reaction in a rabbit model of glaucoma drainage implant surgery. METHODS Adult New Zealand White rabbits had glaucoma drainage device implantation using Model FP8 Ahmed glaucoma valves. One eye was randomly assigned to receive postoperative intrableb injection of pirfenidone followed by...

متن کامل

Evaluation of bleb characteristics after implantation of the EX-PRESS™ glaucoma filtration device

PURPOSE To compare bleb survival and histology after implantation of the EX-PRESS™ glaucoma filtration device versus silicone tubes in a rabbit model of filtration surgery. METHODS Glaucoma filtration surgery was performed on one eye each of twelve New Zealand white rabbits. Eyes were randomized to implantation with the EX-PRESS™ filtration device (n=6) or a silicone tube (n=6). Bleb vascular...

متن کامل

New implant for drainage in glaucoma. Animal trial.

The implant described in this communication is the direct descendent of a long series of artificial drainage devices which began when Zorab (I9I2) inserted a silk thread through the limbus in order to drain aqueous into the subconjunctival space in cases of glaucoma (see also Mayou, I9I2). Among the more recently described devices are teflon drainage tubes in man (Richards, I955; Epstein, 1959;...

متن کامل

Motility disturbance due to true Tenon cyst in a child with a Baerveldt glaucoma drainage implant.

Epithelial ingrowth of the bleb cavity, a true Tenon cyst, is a rare complication of a glaucoma drainage implant. Previous cases have been associated with persistent bleb leak, and most have occurred in eyes with prior extraocular surgery. We describe a case of a true Tenon cyst causing strabismus and an elevated intraocular pressure that was successfully treated by surgical revision.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 133 5  شماره 

صفحات  -

تاریخ انتشار 2015