Correction of the anion gap for albumin in order to detect occult tissue anions in shock.
نویسندگان
چکیده
BACKGROUND It is believed that hypoalbuminaemia confounds interpretation of the anion gap (AG) unless corrected for serum albumin in critically ill children with shock. AIM To compare the ability of the AG and the albumin corrected anion gap (CAG) to detect the presence of occult tissue anions. METHODS Prospective observational study in children with shock in a 22 bed multidisciplinary paediatric intensive care unit of a university childrenrsquo;s hospital. Blood was sampled at admission and at 24 hours, for acid-base parameters, serum albumin, and electrolytes. Occult tissue anions (lactate + truly "unmeasured" anions) were calculated from the strong ion gap. The anion gap ((Na + K) - (Cl + bicarbonate)) was corrected for serum albumin using the equation of Figge: AG + (0.25 x (44 - albumin)). Occult tissue anions (TA) predicted by the anion gap were calculated by (anion gap - 15 mEq/l). Optimal cut off values of anion gap were compared by means of receiver operating characteristic (ROC) curves. Ninety three sets of data from 55 children (median age 7 months, median weight 4.9 kg) were analysed. Data are expressed as mean (SD), and mean bias (limits of agreement). RESULTS The incidence of hypoalbuminaemia was 76% (n = 42/55). Mean serum albumin was 25 g/l (SD 8). Mean AG was 15.0 mEq/l (SD 6.1), compared to the CAG of 19.9 mEq/l (SD 6.6). Mean TA was 10.2 mmol/l (SD 6.3). The AG underestimated TA with mean bias 10.2 mmol/l (4.1-16.1), compared to the CAG, mean bias 5.3 mmol/l (0.4-10.2). A clinically significant increase of TA >5 mmol/l was present in 83% (n = 77/93) of samples, of which the AG detected 48% (n = 36/77), and the CAG 87% (n = 67/77). Post hoc ROC analysis revealed optimal cut off values for detection of TA >5 mmol/l to be AG >10 mEq/l, and CAG >15.5 mEq/l. CONCLUSION Hypoalbuminaemia is common in critically ill children with shock, and is associated with a low observed anion gap that may fail to detect clinically significant amounts of lactate and other occult tissue anions. We suggest that the albumin corrected anion gap should be calculated to screen for occult tissue anions in these children.
منابع مشابه
An Improvement to the Properties of GAP Binder with Energetic Ionic Liquids
Glycidyl azide polymer (GAP) is used as a binder in the propellants. Energetic ionic liquids are used as a plasticizer to correct the properties of polymer. In this study, first ionic liquid was bonded to the GAP by certain amount and then the energetic anions of nitrate (NO3) and azide (N3) were used to exchange anion. FTIR analyses confirm accurately anions exchange. DSC, viscometer and heat ...
متن کاملAnion gap, anion gap corrected for albumin, base deficit and unmeasured anions in critically ill patients: implications on the assessment of metabolic acidosis and the diagnosis of hyperlactatemia
BACKGROUND Base deficit (BD), anion gap (AG), and albumin corrected anion gap (ACAG) are used by clinicians to assess the presence or absence of hyperlactatemia (HL). We set out to determine if these tools can diagnose the presence of HL using cotemporaneous samples. METHODS We conducted a chart review of ICU patients who had cotemporaneous arterial blood gas, serum chemistry, serum albumin (...
متن کاملAdsorptive Behavior of an Amberlite Anion Exchanger Resin for Uranium (VI) Sorption in the Presence of Sulfate Anions
Uranium (VI) sorption using an anionic exchanger resin in the presence of sulfate anions, namely amberlite 910, was the subject of current study. Batch sorption experiments were carried out to evaluate the influence of operational parameters such as pH, contact time, initial concentration and existence of various anions (including phosphate, sulfate, chloride, fluoride, and nitrate) in the solu...
متن کاملUranium Ions Removal Using Amberlite CG-400 Anion Exchanger Resin in the Presence of Sulfate Anions
Uptake of uranium (VI) ions using an anion exchanger resin, namely amberlite CG-400, was studied through this work in the presence of sulfate anions. Impact of various parameters including pH, contact time, initial concentration of uranium ions and intrusion with different anion contents (phosphate, chloride,sulfate, nitrate and fluoride) was examined on the sorption performance of the resin. A...
متن کاملUranium Removal from Aqueous Solution Using Ion-Exchange Resin DOWEX® 2x8 in the Presence of Sulfate Anions
The current study was attributed to uranium (VI) ions adsorption using a anion exchanger resin, Dowex®2x8, in the presence of sulfate anions. Evaluation of operational parameters including contact time, pH, initial concentration of uranium ions, and presence of various anions (including phosphate, sulfate, chloride, fluoride, and nitrate) in the solution was assessed on sorption performance of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of disease in childhood
دوره 87 6 شماره
صفحات -
تاریخ انتشار 2002