Quantitative analysis of trace palladium contamination in solution using electrochemical X-ray fluorescence (EC-XRF).

نویسندگان

  • Zoë J Ayres
  • Mark E Newton
  • Julie V Macpherson
چکیده

The application of electrochemical X-ray fluorescence (EC-XRF), for the detection of palladium (Pd) contamination in a range of solutions containing electrochemically active compounds, present in excess and relevant to the pharmaceutical and food industries, is reported. In EC-XRF, EC is used to electrochemically pre-concentrate metal on an electrode under forced convection conditions, whilst XRF is employed to spectroscopically quantify the amount of metal deposited, which quantitatively correlates with the original metal concentration in solution. Boron doped diamond is used as the electrode due to its very wide cathodic window and the fact that B and C are non-interfering elements for XRF analysis. The effect of several parameters on the Pd XRF signal intensity are explored including: deposition potential (Edep), deposition time (tdep) and Pd(2+) concentration, [Pd(2+)]. Under high deposition potentials (Edep = -1.5 V), the Pd XRF peak intensity varies linearly with both tdep and [Pd(2+)]. Quantification of [Pd(2+)] is demonstrated in the presence of excess acetaminophen (ACM), l-ascorbic acid, caffeine and riboflavin. We show the same Pd XRF signal intensity (for [Pd(2+)] = 1.1 μM and tdep = 325 s) is observed, i.e. same amount of Pd is deposited on the electrode surface, irrespective of whether these redox active molecules are present or absent. For tdep = 900 s we report a limit of detection for [Pd(2+)] of 3.6 ppb (34 nM). Even lower LODs are possible by increasing tdep or by optimising the X-ray source specifically for Pd. The work presented for Pd detection in the presence of ACM, achieves the required detection sensitivity stipulated by international pharmacopeia guidelines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a quantitative method for trace impurities in arsenous acids by synchrotron radiation X-ray fluorescence spectrometry and inductively coupled plasma-atomic emission spectrometry.

Thirteen arsenous acid samples of known origins and refining methods were collected. Each sample was subjected to quantitative analysis of any impurity elements present using synchrotron radiation X-ray fluorescence spectrometry (SR-XRF) and inductively coupled plasma-atomic emission spectrometry (ICP-AES). The trace elements selected were Sn, Sb and Bi for the reasons that they were considered...

متن کامل

Quantitative Analysis of Rock Samples by an X-ray Fluorescence Spectrometer (ii)

One of the advantages of X-ray fluorescence XRF analysis is its ability to perform accurate quantitative analysis over a wide range of elements with relative ease. In addition, its high sensitivity makes it ideal for trace elemental analysis. The establishment of analytical conditions for XRF is straightforward, including the determination of spectral line overlap correction factors. As with mo...

متن کامل

Grazing-exit and micro X-ray fluorescence analyses for chemical microchips.

Grazing-exit x-ray fluorescence (GE-XRF) and micro x-ray fluorescence (micro-XRF) methods were applied to chemical microchips as a detection method. Since an energy-dispersive x-ray detector was used, the simultaneous detection of multiple elements was possible. An analyzing region was especially designed on the microchip so that a sample solution could be dried and concentrated in a suitable a...

متن کامل

Simultaneous X-ray Nano-Ptychographic and Fluorescence Microscopy at the Bionanoprobe

Hard X-ray fluorescence (XRF) microscopy offers unparalleled sensitivity for quantitative analysis of most of the trace elements in biological samples, such as Fe, Cu, and Zn. These trace elements play critical roles in many biological processes. With the advanced nano-focusing optics, nowadays hard X-rays can be focused down to 30 nm or below and can probe trace elements within subcellular com...

متن کامل

Determining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry

The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method,  and the formation of beads. Certified reference bauxite samples were used for the cali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 141 11  شماره 

صفحات  -

تاریخ انتشار 2016