In vivo finite element model-based image analysis of pacemaker lead mechanics
نویسندگان
چکیده
BACKGROUND Fractures of implanted pacemaker leads are currently identified by inspecting radiographic images without making full use of a priori known material and structural information. Moreover, lead designers are unable to incorporate clinical image data into analyses of lead mechanics. METHODS A novel finite element/active contour method was developed to quantify the in vivo mechanics of implanted leads by estimating the distributions of stress, strain, and traction using biplane videoradiographic images. The nonlinear equilibrium equations governing a thin elastic beam undergoing 3-D large rotation were solved using one-dimensional isoparametric finite elements. External forces based on local image greyscale values were computed from each pair of images using a perspective transformation governing the relationship between the image planes. RESULTS Cantilever beam forward solution results were within 0.2% of the analytic solution for a wide range of applied loads. The finite element/active contour model was able to reproduce the principal curvatures of a synthetic helix within 3% of the analytic solution and estimates of the helix's geometric torsion were within 20% of the analytic solution. Applying the method to biplane videoradiographic images of a lead acutely implanted in an anesthetized dog resulted in expected variations in curvature and bending stress between compliant and rigid segments of the lead. CONCLUSIONS By incorporating knowledge about lead geometric and material properties, the 3-D finite element/active contour method regularizes the image reconstruction problem and allows for more quantitative and automatic assessment of implanted lead mechanics.
منابع مشابه
Fracture Mechanics Analysis of Fourth Lumbar Vertebra in Method of Finite Element Analysis
Objective: In this paper, finite element model of the L4 vertebra subjected to combination of compression and flexion loading in isotropic and anisotropic cases is investigated. Methods: In both cases, the vertebra is considered homogeneous. Also, the body of vertebra is divided to cancellous and cortical sections in anisotropic model, but the process is assumed isotropic such as isotropic mode...
متن کاملhp-Spectral Finite Element Analysis of Shear Deformable Beams and Plates
There are different finite element models in place for predicting the bending behavior of shear deformable beams and plates. Mostly, the literature abounds with traditional equi-spaced Langrange based low order finite element approximations using displacement formulations. However, the finite element models of Timoshenko beams and Mindlin plates with linear interpolation of all generalized disp...
متن کاملFracture Mechanics Analysis of Fourth Lumbar Vertebra in Method of Finite Element Analysis
Objective: In this paper, finite element model of the L4 vertebra subjected to combination of compression and flexion loading in isotropic and anisotropic cases is investigated. Methods: In both cases, the vertebra is considered homogeneous. Also, the body of vertebra is divided to cancellous and cortical sections in anisotropic model, but the process is assumed isotropic such as isotropic mode...
متن کاملFinite Element Simulation of Contact Mechanics of Cancer Cells in Manipulation Based on Atomic Force Microscopy
The theory of contact mechanics deals with stresses and deformations which arise when the surfaces of two solid bodies are brought into contact. In elastic deformation contact occurs over a finite area. A regular method for determining the dimensions of this area is Hertz Contact Model. Appearance of atomic force microscope results in introduction of Contact ...
متن کاملStress Field Analysis of V-Notches with Tip Cracks in a Polymer Material Using Digital Image Correlation
In this study, displacement field around v-notches of a poly methyl metha crylate (PMMA) specimen with tip cracks will be analyzed using digital image correlation technique. First intensity factor in combination with in-plane rigid body translations and rotation components will be determined by linear least squares fitting of the displacement field data to the corresponding relations among stre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image analysis
دوره 5 4 شماره
صفحات -
تاریخ انتشار 2001