Long-term stability of angle-stable versus conventional locked intramedullary nails in distal tibia fractures

نویسندگان

  • Dirk Wähnert
  • Yves Stolarczyk
  • Konrad L Hoffmeier
  • Michael J Raschke
  • Gunther O Hofmann
  • Thomas Mückley
چکیده

BACKGROUND In the last years intramedullary nailing has become the treatment of choice for most displaced diaphyseal tibia fractures. In contrast intramedullary nailing of distal tibia fractures is accompanied by problems like decreased biomechanical stability. Nevertheless the indications for intramedullary nailing have been extended to include even more distal fractures. The purpose of this study was to compare long-term mechanical characteristics of angle-stable versus conventional locked intramedullary nails in the treatment of unstable distal tibia fractures. Therefore, the effect of time on the mechanical properties of biodegradable sleeves was assessed. METHODS 8 pairs of fresh, frozen porcine tibiae were used. The expert tibial nail (Synthes) was equipped with either three conventional locking screws (CL) or the angle-stable locking system (AS), consisting of a special ASLS screw and a biodegradable sleeve. Biomechanical testing included torsional and axial loading at different time-points over 12 weeks. RESULTS The AS group showed a significantly higher torsional stiffness at all time-points (at least 60%) compared to the CL group (p < 0.001). The neutral zone was at least 5 times higher in the CL group (p < 0.001). The mean axial stiffness was maximum 10% higher (week 6) in the angle-stable locked group compared to the conventional group. There was no significant change of the torsional mechanical characteristics over the 12 weeks in both groups (p > 0.05). For axial stiffness and range of motion significant differences were found in the AS group. CONCLUSIONS The angle-stable locking system (ASLS) with the biodegradable sleeve provides significantly higher long-term stability. Especially the differences determined under torsional loading in this study may have clinical relevance. The ASLS permits the potential to decrease complications like secondary loss of reduction and mal-/non-union.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.

OBJECTIVE To compare the fixation stability of intramedullary nails to that of locked plates for the treatment of distal metaphyseal tibia and fibula fractures. METHODS A simulated, distal metaphyseal tibia fracture was created in 8 pairs of cadaveric tibia-fibula specimens. One of each pair was treated using an intramedullary nail (Trigen IM Nail System; SN Richards, Memphis, TN) and the oth...

متن کامل

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experimen...

متن کامل

Treatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails

  Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...

متن کامل

Treatment of tibial diaphyseal fractures with closed flexible intramedullary ender nails: 39 fractures followed for a period of two to seven years.

OBJECTIVE To assess the efficacy of flexible intramedullary Ender nails for the treatment of tibial diaphyseal. MATERIALS AND METHODS This is a retrospective review of patients treated with the Ender Nail for both open and closed tibial shaft fractures. Between January 1989 and December 1994, 43 fractures were treated with these nails. The configuration of each fracture was determined using t...

متن کامل

Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

Objectives Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the compl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013