Overlapping Melodic Alarms Are Almost Indiscriminable
نویسندگان
چکیده
OBJECTIVE We explore how accurately and quickly nurses can identify melodic medical equipment alarms when no mnemonics are used, when alarms may overlap, and when concurrent tasks are performed. BACKGROUND The international standard IEC 60601-1-8 (International Electrotechnical Commission, 2005) has proposed simple melodies to distinguish seven alarm sources. Previous studies with nonmedical participants reveal poor learning of melodic alarms and persistent confusions between some of them. The effects of domain expertise, concurrent tasks, and alarm overlaps are unknown. METHOD Fourteen intensive care and general medical unit nurses learned the melodic alarms without mnemonics in two sessions on separate days. In the second half of Day 2 the nurses identified single alarms or pairs of alarms played in sequential, partially overlapping, or nearly completely overlapping configurations. For half the experimental blocks nurses performed a concurrent mental arithmetic task. RESULTS Nurses' learning was poor and was no better than the learning of nonnurses in a previous study. Nurses showed the previously noted confusions between alarms. Overlapping alarms were exceptionally difficult to identify. The concurrent task affected response time but not accuracy. CONCLUSION Because of a failure of auditory stream segregation, the melodic alarms cannot be discriminated when they overlap. Directives to sequence the sounding of alarms in medical electrical equipment must be strictly adhered to, or the alarms must redesigned to support better auditory streaming. APPLICATION Actual or potential uses of this research include the implementation of IEC 60601-1-8 alarms in medical electrical equipment.
منابع مشابه
Are melodic medical equipment alarms easily learned?
BACKGROUND We tested melodic auditory alarms recommended in the IEC 60601-1-8 standard for medical electrical equipment for ease of learning and discrimination, and for effectiveness during a timeshared task. METHODS Twenty-two critical care nurses learned the IEC 60601-1-8 melodic alarms over two training sessions more than a week apart, with or without mnemonics suggested in the standard. S...
متن کاملLearnability and discriminability of melodic medical equipment alarms.
Melodic alarms proposed in the IEC 60601-1-8 standard for medical electrical equipment were tested for learnability and discriminability. Thirty-three non-anaesthetist participants learned the alarms over two sessions of practice, with or without mnemonics suggested in the standard. Fewer than 30% of participants could identify the alarms with 100% accuracy at the end of practice. Confusions pe...
متن کاملDo mnemonics help nurses learn melodic medical equipment alarms?
We tested the melodic alarms and mnemonics proposed in the international standard for alarms used in medical electrical equipment (IEC 60601-1-8) for learnability and discriminability, with 14 registered nurses over two days, approximately a week apart. Two learning modes (Mnemonics and No Mnemonics) were examined in computer administered tests. The first experimental group was supplied with mn...
متن کاملA Pattern Extraction Algorithm for Abstract Melodic Representations that Allow Partial Overlapping of Intervallic Categories
This paper proposes an efficient pattern extraction algorithm that can be applied on melodic sequences that are represented as strings of abstract intervallic symbols; the melodic representation introduces special “don’t care” symbols for intervals that may belong to two partially overlapping intervallic categories. As a special case the well established “step-leap” representation is examined. ...
متن کامل"For if the trumpet give an uncertain sound, who shall prepare himself to the battle?" (I Corinthians 14:8, KJV).
Frank E. Block, Jr., MD Every clinician is well aware of the problems with audible alarms: False alarms, loud alarms, difficulty determining what is alarming, and inability to quiet an alarm all create distractions that impede patient care. These problems are complicated by the different approaches to alarms among devices. Devices designed by various manufacturers may use different alarm sounds...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Human factors
دوره 49 4 شماره
صفحات -
تاریخ انتشار 2007