Comparing methods to estimate the human lens power.

نویسندگان

  • Jos J Rozema
  • David A Atchison
  • Marie-José Tassignon
چکیده

UNLABELLED PURPOSE. To compare the accuracy of different methods of calculating human lens power when lens thickness is not available. METHODS. Lens power was calculated by four METHODS Three methods were used with previously published biometry and refraction data of 184 emmetropic and myopic eyes of 184 subjects (age range, 18-63 years; spherical equivalent range, -12.38 to +0.75 D). These three methods consist of the Bennett method, which uses lens thickness, a modification of the Stenström method and the Bennett-Rabbetts method, both of which do not require knowledge of lens thickness. These methods include c constants, which represent distances from lens surfaces to principal planes. Lens powers calculated with these methods were compared with those calculated using phakometry data available for a subgroup of 66 emmetropic eyes (66 subjects). RESULTS. Lens powers obtained from the Bennett method corresponded well with those obtained by phakometry for emmetropic eyes, although individual differences up to 3.5 D occurred. Lens powers obtained from the modified-Stenström and Bennett-Rabbetts methods deviated significantly from those obtained with either the Bennett method or phakometry. Customizing the c constants improved this agreement, but applying these constants to the entire group gave mean lens power differences of 0.71 ± 0.56 D compared with the Bennett method: By further optimizing the c constants, the agreement with the Bennett method was within ±1 D for 95% of the eyes. CONCLUSIONS. With appropriate constants, the modified Stenström and Bennett-Rabbetts methods provide a good approximation of the Bennett lens power in emmetropic and myopic eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye

Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...

متن کامل

Quantum mechanical proton range in human body

Introduction: Proton therapy delivers radiation to tumor tissue in a much more confined way than conventional photon therapy thus allowing the radiation oncologist to use a greater dose while still minimizing side.   Materials and Methods: protons release most of their energy within the tumor region. As a result, the treating physician can potentially give an...

متن کامل

Human lens transmission of blue light: a comparison of autofluorescence-based and direct spectral transmission determination.

PURPOSE Direct measurement of the transmission of light through the human lens is not possible in vivo unless invasive techniques are used. In the current study, a reliable in vivo estimate of the transmission of blue light through the lens was assessed by comparing an indirect and noninvasive method based on autofluorescence measurements with a direct method. METHODS Total transmission of bl...

متن کامل

An Estimate of Radiation Dose to the Lens of the Eyes, Parotid Gland, and Thyroid Gland in Dental Panoramic Radiography

Introduction: Dental panoramic radiography (DPR) is one of the most frequent diagnostic X-ray procedures, the application of which is currently on a growing trend. During DPR, several radiosensitive tissues, such as the lens of the eyes, parotid gland, and thyroid gland, contribute to the radiation field, and it is necessary to monitor their received dose. The aim of t...

متن کامل

Comparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam

Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 11  شماره 

صفحات  -

تاریخ انتشار 2011