Skeletal scintigraphy with technetium-99m-tetraphenyl porphyrin sulfonate for the detection and determination of osteomyelitis in an animal model.
نویسندگان
چکیده
UNLABELLED This article explores the accumulation of 99mTc-tetraphenyl porphyrin sulfonate (TPPS4) at inflammatory sites, especially osteomyelitis, and compares the results with 111In Cl3 and 111In-WBC in an animal model. METHODS Osteomyelitis was induced in 12 New Zealand white rabbits by injecting staphylococcus aureus in the left tibia. Three weeks later, radiographs confirmed the disease. Two hours later, after injection of 74 MBq 99mTc-TPPS4, scintiphotos of the lower extremities were acquired and repeat scintiphotos were obtained 24 hr after injection of 5.55 MBq 111In Cl3. After these studies, 24- and 48-hr scintiphotos of the lower extremities were acquired after injecting 5.55 MBq 111In-labeled WBC. RESULTS The left tibia averaged three times the uptake with 99mTc-TPPS4 compared with right tibia; with 111In Cl3 and 111In WBC the ratios are two times. These three radiopharmaceuticals reveal positive images, but the image quality using 99mTc-TPPS4 is better, as would be expected from the more favorable physical characteristics of 99mTc and the higher uptake. CONCLUSION The traditional combination of three-phase bone and 67Ga-citrate scintigraphy can be replaced by a single injection of 99mTc-TPPS4 with imaging as early as 2 hr. Finally, the use 99mTc-TPPS4 should result in a substantial reduction in radiopharmaceutical cost.
منابع مشابه
The effect of prednisolone on the sensitivity of Technetium 99m-methylene diphosphonate ( 99m Tc-MDP) scintigraphy to detect simulated closed fracture in the rat tibia
Introduction: The purpose of the present study was to evaluate the effect of prednisolone on the sensitivity of bone scanning to detect the simulated closed fracture in the rat tibia. Methods: A total number of forty eight adult, male NMRI rats randomly assigned into two parts, one part for 4 and other for 8 weeks experiments. Each part has been divided into four groups, one group not receivi...
متن کاملConstruction of an Ion-Selective Eelectrode for Determination of permanganate Ion
A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
متن کاملMultiple myeloma in a patient with suspected hyperparathyroidism
Multiple myeloma (MM) is a clonal B-lymphocyte neoplasm of terminally differentiated plasma cells. Imaging modalities which allow the recognition of the effects of myeloma cells on the skeletal system have been utilized for a long time. Herein, we represent a patient with generalized osteoporosis and hypercalcemia, who was referred for parathyroid scan, in whom the widespread bone marrow techne...
متن کاملDiagnostic Value of Technetium-99m-Dimercaptosuccinic Acid Scintigraphy in Prediction of Vesicoureteral Reflux in Children with First-time Febrile Urinary Tract Infection
Background: Imaging modalities such as voiding cystourethrography (VCUG), direct radionuclide cystography (DRNC), and renal cortical scintigraphy (RCS) with technetium-99m dimercaptosuccinic acid (Tc-99mDMSA), are helpful in detecting possible abnormalities of urinary tract such as vesicoureteral reflux (VUR). However, there are confounding data regarding the preference of these modalities. In ...
متن کاملDoes fluid restriction affect the image quality of skeletal scintigraphy?
Introduction: In Islamic countries in the month of Holy Ramadan many Muslims based on their religious Legislation refuse fluid intake during the fasting time though instructed to drink after injection of Tc-99m Methylene-diphosphonates [Tc-99m MDP] used for skeletal scintigraphy. We aimed to establish whether fluid restriction in Tc-99m MDP skeletal scintigraphy has an impact on its quality. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 38 12 شماره
صفحات -
تاریخ انتشار 1997