FEM based Reactance Computation for Transformer Winding Deformation Detection

نویسندگان

  • M.Arivamudhan
  • S.Santhi
چکیده

Leakage reactance is one of the most important specifications in transformer that has significant impact on its overall design. Variation in leakage reactance serves as a diagnostic measure to indicate mechanical integrity of power transformers before and after a short circuit test that demonstrates mechanical strength of transformer windings. This paper presents an approach for leakage reactance computation through finite element method (FEM) and subsequent analysis of winding deformation due to a short circuit. A concentric two winding transformer is considered and reactance computation is made using FEM package. The results of computation are compared against classical method. It is observed that the method can provide sufficient theoretical basis for improving the design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Auto-transformer Mechanical Faults Diagnosis ‎Using Finite Element based FRA

Frequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in...

متن کامل

Efficiency Improvement of the Flyback Converter Based on High Frequency Transformer Winding Rearrangement

In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...

متن کامل

A Coupled Thermal-Electromagnetic FEM Model to Characterize the Thermal Behavior of Power Transformers Damaged By Short Circuit Faults

This research work is an initiative to characterize the thermal behavior of power transformers in presence of winding short circuit faults as one of the most important causes of failures in power transformers. The paper contributes for this matter by accurately estimating the excessive power losses and temperature rise due to winding short circuit faults, through a circuit-magnetic-thermal FEM ...

متن کامل

A Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum

Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014