Preparation of diethylaminoethyl hollow fibres for high-flow liquid chromatography.

نویسندگان

  • A C Tsuei
  • V C Yang
چکیده

A novel anion-exchange column for fast-flow liquid chromatography was developed. The column was prepared by immobilizing diethylaminoethyl groups on to the inner walls of regenerated cellulose hollow fibres. A detailed investigation was conducted of the parameters affecting diethylaminoethyl immobilization such as the NaOH concentration, the reaction temperature, the diethylaminoethyl concentration and the reaction span. Based upon the findings, a protocol to optimize the preparation of the diethylaminoethyl hollow fibres was established. The diethylaminoethyl hollow fibres prepared adsorbed 186 +/- 30 mg of albumin/g fibres.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

Development of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples

A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...

متن کامل

Solid Phase Extraction for 1-Hydroxypyrene as a Biomarker of Occupational Exposure to PAHs Prior to High Performance Liquid Chromatography

Urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. In this study, solid phase extraction was appropriately conditioned with regard to sample pH, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. Octadecyl silica cartridge (C<su...

متن کامل

Preparation and Characterisation of Immunoadsorbents for High Performance Liquid Affinity Chromatography (HPLAC)

The efficacy of activation methods and coupling were studied in the context of performance in batch and fixed bed binding experiments utilizing cell culture fluids or blood plasma as feedstock. Conclusions were drawn regarding selection of solid phase according to pore size, rigidity, pH stability, Chemistry of derivation and activation, and gross concentration of immobilized ligand require...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomaterials

دوره 11 9  شماره 

صفحات  -

تاریخ انتشار 1990