The design of a laboratory facility for evaluating the structural response of small-diameter buried pipes
نویسنده
چکیده
The design of a new laboratory facility for evaluating the structural response of small-diameter buried pipes (e.g., leachate collection pipes in landfills) is presented. The pipe is tested within a 2.0 m wide, 2.0 m long, and 1.6 m high prism of soil, subject to large vertical pressures (1000 kPa), with only minimal roughness and deflection of the lateral boundaries. Results from finite element analyses are presented to examine the effect of proximity, roughness, and stiffness of the lateral boundary on the soil and pipe response and how reasonable the laboratory idealizations are relative to the deep burial conditions expected to prevail in the field. Shear stresses arising from the roughness of the lateral boundaries alter the stresses acting around the pipe and reduce the proportion of the applied surcharge reaching the pipe. Outward deflection of the lateral boundaries also alters the stress state around the pipe, predominantly resulting from decreases in horizontal stresses within the soil. Reducing boundary friction to less than 5° and limiting the boundary deformation to less than 1 mm at a vertical surcharge of 1000 kPa provide a good idealization of field conditions for a deeply buried pipe.
منابع مشابه
The Investigation of Subsidence Effect on Buried Pipes in 3D Space
Buried pipes in the modern societies are considered as lifelines with a vital and essential role in the human life cycle. The performance of buried pipes is affected by many factors such as ground surface subsidence. In this paper, the effect of subsidence on pipelines is investigated using a three-dimensional numerical modeling developed in FLAC3D software for four types of most commonly used ...
متن کاملSoil-Structure Interaction of Buried Pipes Under Cyclic Loading Conditions
The safety of lifelines, as the most important urban facilities, under different conditions highly depends on the safe design and performance of these buried structures. This cannot be achieved unless their actual behaviors are well understood and considered at the designing stage. A new physical model was developed in Amirkabir University of Technology to study the behavior of buried pipes und...
متن کاملA Continuum Shell-beam Finite Element Modeling of Buried Pipes with 90-degree Elbow Subjected to Earthquake Excitations
In the current work, the seismic analysis of bent region in buried pipes is performed, and effects of soil properties and modeling methods on pipe’s response are investigated. To do this task Beam, Beam-Shell Finite Element modeling and a Continuum shell FE models of a 90 degrees elbow are employed. In the Beam model, the pipe is simulated by beam elements while combined shell-beam elements a...
متن کاملHealth Monitoring of Welded Steel Pipes by Vibration Analysis
In the present work, structure health monitoring (SHM) of welded steel pipes was used to diagnosis their state via vibration based damage detection techniques. The dynamic quantities such as Frequency Response Functions (FRFs), mode shapes and modal parameters from structural vibration to detect damage were measured, set on linear averaging mode, with a maximum frequency of analysis of 3.2 kHz....
متن کاملBlast Mitigation Analysis of Semi-Buried Structure
Semi-buried structures are most commonly used at first line of defense along the border between two countries. This demands investigation of their dynamic behaviour under blast loading. Herein, a semi-buried structure with foam sandwiched walls and buttresses to reduce the effect of blast is analysed. The effect of provision of different configurations of buttresses and foam core between two la...
متن کامل