Using the ORTEC ISO-CART and ISOTOPIC Software for In Situ Gamma Spectrosocpy Measurements of Bulk Samples
ثبت نشده
چکیده
The portable high-resolution spectroscopy system includes an HPGe detector and an ORTEC digiDART (Figure 2). The HPGe detector includes a 3-, 5-, or 7-liter multi-attitude Dewar that allows the detector to be positioned in many directions without a significant loss of liquid nitrogen. The digiDART provides the battery-operated digital spectroscopy system which (1) applies high voltage to the detector, (2) acquires and stores the data, and (3) provides limited data manipulation ability. The digiDART is designed to operate on battery power for a working day. The digiDART can also be interfaced to a portable computer for an complete on-the-spot analysis. Using the ORTEC ISO-CART and ISOTOPIC Software for In-Situ Gamma Spectroscopy Measurements of Bulk Samples ORTEC ®
منابع مشابه
A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region
Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...
متن کاملStudy of Two Phase Fluid Flow in Water Wet Reservoir Rocks by Using X-Ray In situ Saturation Monitoring
Displacement of oil and water in porous media of reservoir rocks is described by relative permeability curves, which are important input data for reservoir performance simulation and drive mechanism studies. Many core studies, such as multiphase relative permeability, capillary pressure and saturation exponent determination, depend on the volume fractions of multiphase flui...
متن کاملCharacterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron
Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...
متن کاملPreparation of Flame Retardant Polystyrene via In-Situ Bulk Polymerization Method and Evaluation of its Flammability Properties
In this study, in-situ bulk polymerization was investigated for obtaining flame retardant polystyrene (PS). The halogenated and phosphoric compounds were used as flame retardant additives and Perkadox 30 was used as a synergist. The flammability of the PS was evaluated by thermogravimetric analyzer (TGA), limiting oxygen index (LOI) and UL-94 tests. The results show that polymerization process ...
متن کاملOptimization of measurement counting time in Gamma-ray spectrometry of soil samples
The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...
متن کامل