Physiological impact of the N95 filtering facepiece respirator on healthcare workers.

نویسندگان

  • Raymond J Roberge
  • Aitor Coca
  • W Jon Williams
  • Jeffrey B Powell
  • Andrew J Palmiero
چکیده

OBJECTIVE To assess the physiological impact of the N95 filtering facepiece respirator (FFR) on healthcare workers. METHODS Ten healthcare workers each conducted multiple 1-hour treadmill walking sessions, at 1.7 miles/h, and at 2.5 miles/h, while wearing FFR with exhalation valve, FFR without exhalation valve, and without FFR (control session). We monitored heart rate, respiratory rate, tidal volume, minute volume, blood oxygen saturation, and transcutaneously measured P(CO2). We also measured user comfort and exertion, FFR moisture retention, and the carbon dioxide and oxygen concentrations in the FFR's dead space. RESULTS There were no significant differences between FFR and control in the physiological variables, exertion scores, or comfort scores. There was no significant difference in moisture retention between FFR with and without exhalation valve. Two subjects had peak P(CO2) > or = 50 mm Hg. The FFR with exhalation valve offered no benefit in physiological burden over the FFR without valve. The FFR dead-space oxygen and carbon dioxide levels did not meet the Occupational Safety and Health Administration's ambient workplace standards. CONCLUSIONS In healthy healthcare workers, FFR did not impose any important physiological burden during 1 hour of use, at realistic clinical work rates, but the FFR dead-space carbon dioxide and oxygen levels were significantly above and below, respectively, the ambient workplace standards, and elevated P(CO2) is a possibility. Exhalation valve did not significantly ameliorate the FFR's P(CO2) impact.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden.

Growing concern over the availability of Respiratory protective devices (eg, filtering facepiece Respirators), in the face of the probable extreme demand brought on by a pandemic influenza, has prompted the suggestion that useful life of N95 filtering facepiece Respirator can be extended by the concurrent use of a surgical mask as an outer protective barrier over the Respirator. Personal protec...

متن کامل

Evaluation of the Filtration Efficiency of the N95 Filtering Facepiece Respirator for Airborne Methicillin-Resistant Staphylococcus aureus

Airborne methicillin-resistant Staphylococcus aureus (MRSA) was detected inside a swine facility that presented a risk of respiratory colonization and infection to swine and swine workers. Viable airborne MRSA was sampled using an Andersen cascade impactor, and total airborne particulates were sampled using an optical particle counter. The filter efficiency of the N95 filtering facepiece respir...

متن کامل

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...

متن کامل

Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators

Disposable N95 filtering facepiece respirators (FFRs) certified by the National Institute for Occupational Safety and Health (NIOSH) are widely used by healthcare workers to reduce exposures to infectious biological aerosols. There is currently major concern among public health officials about a possible shortage of N95 FFRs during an influenza pandemic. Decontamination and reuse of FFRs is a p...

متن کامل

Performance of Facepiece Respirators and Masks against Surgical Smoke: SWPF Study

Healthcare workers in operating rooms are often exposed to surgical smoke when surgical and invasive procedures are performed by using laser or other devices that interact with tissue. Potentially infectious viruses, bacteria, and hazardous chemicals are found in surgical smoke, which are associated with several respiratory diseases including chronic cough, throat irritation, and asthma. Additi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2010