Evaluation of a new immunoassay for urinary ethyl glucuronide testing.

نویسندگان

  • Michael Böttcher
  • Olof Beck
  • Anders Helander
چکیده

AIMS The minor ethanol metabolite ethyl glucuronide (EtG) is used as a sensitive and specific test for recent alcohol consumption with clinical and forensic applications. This study evaluated a new enzyme immunoassay (DRI-EtG EIA, Microgenics Corp.) for determination of the EtG concentration in urine samples. METHODS Evaluation was done using the kit calibrators (range 0-5.0 mg/L) and controls, an external quality control sample, and 400 consecutive urines from the routine samples pool. The measuring range was extended by dilution of urine samples with saline. Comparison was made with an established liquid chromatographic-mass spectrometric (LC-MS) method. RESULTS The intra- and inter-assay imprecision of the DRI-EtG EIA in the range 0.4-2.5 mg/L was <2.2% (coefficient of variation, CV), and the limit of quantification was <0.1 mg/L. For the 400 urine samples, the EtG concentrations obtained using the DRI-EtG EIA (mean 24.2 mg/L, range 0-830) and LC-MS method (mean 22.4 mg/L, range 0-959) showed an overall good and statistically significant agreement (r2 = 0.931, P < 0.0001). CONCLUSIONS These results indicated a high level of accuracy and selectivity of the DRI-EtG EIA for quantification of urinary EtG. In the absence of a commonly accepted cut-off limit for urinary EtG, a threshold of 0.5 mg/L (2.2 mumol/L) is proposed, to obtain a high sensitivity but avoid positive results due to unintentional ethanol exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the DRI-ETG EIA method for the determination of ethyl glucuronide concentrations in clinical and post-mortem urine.

A commercial enzyme immunoassay for the qualitative and semi-quantitative measurement of ethyl glucuronide (EtG) in urine was evaluated. Post-mortem (n=800), and clinical urine (n=200) samples were assayed using a Hitachi 902 analyzer. The determined concentrations were compared with those obtained using a previously published liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for...

متن کامل

Urinary tract infection: a risk factor for false-negative urinary ethyl glucuronide but not ethyl sulfate in the detection of recent alcohol consumption.

tive Urinary Ethyl Glucuronide but Not Ethyl Sulfate in the Detection of Recent Alcohol Consumption, Anders Helander and Helen Dahl (Department of Clinical Neuroscience, Karolinska Institutet and University Hospital, Stockholm, Sweden; * address correspondence to this author at: Alcohol Laboratory, L7:03, Karolinska University Hospital Solna, SE-171 76 Stockholm, Sweden; fax 46-8-51771532, e-ma...

متن کامل

Detection times for urinary ethyl glucuronide and ethyl sulfate in heavy drinkers during alcohol detoxification.

AIMS Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are conjugated ethanol metabolites formed in low amounts after alcohol consumption. Compared with ethanol, EtG and EtS are excreted in urine for a prolonged time, making them useful as sensitive alcohol biomarkers. This study determined the detection times for EtG and EtS in alcoholic patients undergoing alcohol detoxification. METHODS Alco...

متن کامل

ASSESSMENT AND DETECTION Detection Times for Urinary Ethyl Glucuronide and Ethyl Sulfate in Heavy Drinkers during Alcohol Detoxification

Aims: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are conjugated ethanol metabolites formed in low amounts after alcohol consumption. Compared with ethanol, EtG and EtS are excreted in urine for a prolonged time, making them useful as sensitive alcohol biomarkers. This study determined the detection times for EtG and EtS in alcoholic patients undergoing alcohol detoxification. Methods: Alco...

متن کامل

Comparison between the urinary alcohol markers EtG, EtS, and GTOL/5-HIAA in a controlled drinking experiment.

AIM Urinary ethyl glucuronide (EtG), ethyl sulfate (EtS), and the ratio between 5-hydroxytryptophol-glucuronide and 5-hydroxyindole-3-acetic acid (GTOL/5-HIAA) are all suggested as biomarkers for recent alcohol ingestion with longer detection times than measurement of ethanol itself. The aim of this controlled study was to compare the sensitivities and detection times of EtG, EtS, and GTOL/5-HI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Alcohol and alcoholism

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2008