Detection, 3-D positioning, and sizing of small pore defects using digital radiography and tracking
نویسنده
چکیده
This article presents an algorithm that handles the detection, positioning, and sizing of submillimeter-sized pores in welds using radiographic inspection and tracking. The possibility to detect, position, and size pores which have a low contrast-to-noise ratio increases the value of the nondestructive evaluation of welds by facilitating fatigue life predictions with lower uncertainty. In this article, a multiple hypothesis tracker with an extended Kalman filter is used to track an unknown number of pore indications in a sequence of radiographs as an object is rotated. Each pore is not required to be detected in all radiographs. In addition, in the tracking step, three-dimensional (3-D) positions of pore defects are calculated. To optimize, set up, and pre-evaluate the algorithm, the article explores a design of experimental approach in combination with synthetic radiographs of titanium laser welds containing pore defects. The pre-evaluation on synthetic radiographs at industrially reasonable contrast-to-noise ratios indicate less than 1% false detection rates at high detection rates and less than 0.1mm of positioning errors for more than 90% of the pores. A comparison between experimental results of the presented algorithm and a computerized tomography reference measurement shows qualitatively good agreement in the 3-D positions of approximately 0.1-mm diameter pores in 5-mm-thick Ti-6242.
منابع مشابه
بررسی دقت پانورامیک دیجیتال در تشخیص پوسیدگیهای پروگزیمال
Background and Aims: Conventional radiological equipments in our country are going to be converted to digital system using computed radiology (CR) technology. If we know the accuracy of digital panoramic radiography for detection of small defects in tooth, it will be useful in cases with difficulty for taking the intraoral radiographs. The aim of this study was to evaluate sensitivity and speci...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملComparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography
Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...
متن کاملComparison of computerized digital and analog radiography for detection of bronchial pattern in dogs
Background: Analog radiography has been replaced with digital radiography for canine diagnostic imaging in many veterinary clinics. There is no data comparing these modalities in a veterinary clinical setting to detect bronchial pattern signs in dogs. Objectives: In this study, computerized digital radiography (CR) and analog radiography were compared for diagnosis of bronchial pattern in dogs....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- EURASIP J. Adv. Sig. Proc.
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014