Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study
نویسندگان
چکیده
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.
منابع مشابه
PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE
Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...
متن کاملAutoimmune hepatitis diagnosed by endoscopic ultrasound-guided liver biopsy using a new 19-gauge histology needle.
An 85-year-old woman presented with elevated liver function tests. A computed tomography (CT) scan showed normal liver morphology and a cyst in the pancreas. Viral hepatitis serology was negative but tests for autoimmune disease were positive: antinuclear antibody 1:320, antismooth muscle antibody 1:40, immunoglobulin G level 2600mg/dL. The patient underwent endoscopic ultrasound (EUS)guided fi...
متن کاملComparison of the Tru-cut biopsy needle with the Abrams punch for pleural biopsy.
In a prospective study pleural biopsy specimens obtained with a Tru-cut needle were compared with those obtained with an Abrams pleural biopsy punch from 36 patients in Zimbabwe judged to have an effusion of at least 1.5 litres; one patient had two biopsies. Both instruments were used on each patient, the Abrams punch being followed by the Tru-cut needle. There were no serious complications. Th...
متن کاملTechnique of transurethral needle core biopsy to confirm invasive bladder cancer staging
INTRODUCTION Transurethral, cystoscopically-guided needle core biopsy (TUcoreBxBT) seems to be a less invasive diagnostic method than transurethral resection (TURBT) offering a simple way to confirm cancer infiltration of the bladder. The aim of this study was to assess the technique of TUcoreBxBT in the diagnosis of bladder cancer infiltrating the detrusor muscle. MATERIAL AND METHODS In eve...
متن کاملA comparative trial of liver biopsy needles.
A sheathed needle (Tru-Cut) was compared with a suction biopsy needle (Menghini) in a randomised prospective trial over 18 months to determine whether the former offered any special advantages in routine percutaneous liver biopsy. Seventy-seven consecutive biopsies were performed by a single operator. Although biopsy fragmentation was commoner with the suction needle, the length and volume of t...
متن کامل