Frequency-Shifted Interferometry for Fiber-Optic Sensing

نویسنده

  • Fei Ye
چکیده

Frequency-Shifted Interferometry for Fiber-Optic Sensing Fei Ye Doctor of Philosophy Graduate Department of Electrical and Computer Engineering University of Toronto 2013 This thesis studies frequency-shifted interferometry (FSI), a useful and versatile technique for fiber-optic sensing. I first present FSI theory by describing practical FSI configurations and discussing the parameters that affect system performance. Then, I demonstrate the capabilities of FSI in fiber-optic sensor multiplexing and high sensitivity chemical analysis. We implemented a cryogenic liquid level sensing system in which an array of 3 fiber Bragg grating (FBG) based sensors was interrogated by FSI. Despite sensors’ spectral overlap, FSI is able to separate sensor signals according to their spatial locations and to measure their spectra, from which whether a sensor is in liquid or air can be unambiguously determined. I showed that a broadband source paired with a fast tunable filter can be used in FSI systems as the light source. An array of 9 spectrally overlapping FBGs was successfully measured by such a system, indicating the potential of system cost reduction as well as measurement speed improvement. I invented the the FSI-CRD technique, a highly sensitive FSI-based fiber cavity ring-down (CRD) method capable of deducing minuscule loss change in a fiber cavity from the intensity decay rate of continuous-wave light circulating in the cavity. As a proof-of-principle experiment, I successfully measured the fiber bend loss introduced in the fiber cavity with FSI-CRD, which was found to be 0.172 dB/m at a bend radius of 12.5 mm. We then applied FSI-CRD to evanescent-field sensing. We incorporated fiber tapers as the sensor head in the system and measured the concentration of 1-octyne solutions. A minimum detectable 1-octyne concentration of 0.29% was achieved with measurement sensitivity of 0.0094 dB/% 1-octyne. The same system also accurately detected the concentration change of sodium chloride (NaCl) and glucose solutions. Refractive index sensitivity of 1 dB/RIU with a measurement error of 1 × 10−4 dB was attined for NaCl solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency-Shifted Interferometry — A Versatile Fiber-Optic Sensing Technique

Fiber-optic sensing is a field that is developing at a fast pace. Novel fiber-optic sensor designs and sensing principles constantly open doors for new opportunities. In this paper, we review a fiber-optic sensing technique developed in our research group called frequency-shifted interferometry (FSI). This technique uses a continuous-wave light source, an optical frequency shifter, and a slow d...

متن کامل

Fiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)

The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...

متن کامل

Fiber Optic Interferometric Devices

Fiber optic interferometry can be broadly explained as the techniques that utilize the fundamental principles of optical interference to measure physical sample properties or detect changes via sensing systems that are partially or completely realized using fiber optic components. While the field of optical interference dates back to second half of seventeenth century, the advent of fiber optic...

متن کامل

Quasi-distributed strain sensing with white-light interferometry: a novel approach.

An optical fiber ring is used to generate multiple reference waves in a multiplexed fiber-optic Michelson-type sensor array. The array consists of N sensing segments connected in series along a single optical fiber path and is interrogated with a white-light interferometric technique. Experimental results with a two-sensor array are presented.

متن کامل

Development of a 50mhz Fabry-perot Type Fibre-optic Hydrophone for the Characterisation of Medical Ultrasound Fields

Modern diagnostic medical ultrasound equipment increasingly uses higher frequencies to improve spatial resolution. Higher power ultrasound (US) sources are also being used for therapeutic applications. These higher powered sources cause non-linear propagation of the US within the body and the subsequent harmonic distortion leads to a much wider frequency content of the signal being measured. Ch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013