The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.

نویسندگان

  • Gwangpyo Ko
  • Melvin W First
  • Harriet A Burge
چکیده

In this study, we explored the efficacy of upper-room ultraviolet germicidal irradiation (UVGI) in reducing the concentration of Serratia marcescens and Mycobacterium bovis bacille Calmette-Guérin (BCG) aerosols in enclosed places. We constructed a facility (4.5 m x 3 m x 2.9 m) in which both ceiling- and wall-mounted UV fixtures (UV output: 10W and 5W respectively) were installed. The use of ceiling- and wall-mounted UV fixtures (total UV output: 15W) without mixing fan reduced the concentration of S. marcescens aerosols by 46% (range: 22-80%) at 2 air changes per hour (ACH) and 53% (range: 40-68%) at 6 ACH. The use of ceiling- and wall-mounted UV fixtures with mixing fan increased the UV effectiveness in inactivating S. marcescens aerosols to 62% (range: 50-78%) at 2 ACH and to 86% (81-89%) at 6 ACH. For BCG aerosols, UV effectiveness in inactivating BCG aerosols at 6 ACH were 52% (range: 11-69%) by ceiling-mounted UV fixture only (total UV output: 10W) and 64% (51-83%) by both ceiling- and wall-mounted UV fixtures (total UV output: 15W). Our results indicated that the equivalent ventilation rate attributable to upper-room UVGI for BCG aerosols ranged from 1 ACH to 22 ACH for ceiling-mounted UV fixtures and from 6.4 ACH to 28.5 ACH for ceiling- and wall-mounted UV fixtures. Both generalized linear and generalized additive models were fitted to all our data. The regression results indicated that the number of UV fixtures, use of mixing fan, and air exchange rate significantly affected UV effectiveness (p < 0.01, 0.01, 0.01 respectively). However, the strain difference (S. marcescens vs. BCG) appeared less important in UV effectiveness (p = 0.26). Our results also indicated that UV effectiveness increased at higher temperature ((italic)p(/italic) < 0.01), lower dry-bulb temperature ((italic)p(/italic) = 0.21), and colder air from a supply grill located near the ceiling (p = 0.22).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Bioaerosol Source Location and Ceiling Fan Direction on Eggcrate Upper-room Ultraviolet Germicidal Irradiation

BACKGROUND Eggcrate upper-room ultraviolet germicidal irradiation (UVGI), an engineering control method for reducing the airborne transmission of infectious diseases, was recently developed as an alternative to conventional upper-room UVGI using conventional louvered fixtures. A UV screen, which is composed of open-cell eggcrate panels supported in a frame designed for a conventional suspended ...

متن کامل

Student absenteeism and the comparisons of two sampling procedures for culturable bioaerosol measurement in classrooms with and without upper room ultraviolet germicidal irradiation devices

Upper room ultraviolet germicidal irradiance (UVGI) has been shown to reduce the concentration of bioaerosols in controlled chambers. However, there is a lack of experimental results on the reduction of bioaerosol concentrations by UVGI devices in actual uncontrolled buildings. This study was carried out in an American elementary school in the Midwest. Two sampling procedures were carried out i...

متن کامل

Monitoring human exposures to upper-room germicidal ultraviolet irradiation.

After decades of neglect, the resurgence of tuberculosis in the United States between 1985 and 1992 renewed interest in the use of upper room ultraviolet germicidal irradiation to interrupt the transmission of airborne infections. More recently the bioterrorism threat and the appearance of new pathogens with the potential for airborne spread, such as severe acute respiratory syndrome (SARS), ha...

متن کامل

Minimizing the exposure of airborne pathogens by upper-room ultraviolet germicidal irradiation: an experimental and numerical study.

There has been increasing interest in the use of upper-room ultraviolet germicidal irradiation (UVGI) because of its proven effectiveness in disinfecting airborne pathogens. An improved drift flux mathematical model is developed for optimizing the design of indoor upper-room UVGI systems by predicting the distribution and inactivation of bioaerosols in a ventilation room equipped with a UVGI sy...

متن کامل

Analysis of Efficacy of UVGI Inactivation of Airborne Organisms Using Eulerian and Lagrangian Approaches

Ultraviolet germicidal irradiation (UVGI) is increasingly used in health care facilities to kill airborne bacteria and control the spread of airborne infection among occupants. The most widely used form of UVGI is the passive upper-room lamps that generate a horizontal layer irradiance field above the occupied zone. In this study, the efficacy of killing airborne bacteria by upper-room UVGI in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 110  شماره 

صفحات  -

تاریخ انتشار 2002