A prospective study to assess osseointegration of dental endosseous implants with the Periotest instrument.
نویسنده
چکیده
Long-term studies have documented the successful treatment of edentulous and partially edentulous patients with titanium implants. However, the inability to identify some non-osseointegrated implants before occlusal loading is costly to practitioners and patients. This study followed all patients (n = 40) who had implants placed over a 6-month period. The Periotest instrument was used at Stage II surgery, final impression, prosthesis placement, and 6 and 12 months after occlusal loading to quantify mobility/lack of mobility of implants with conventional 1-piece temporary healing abutments in place. The positive predictive value was 64%. The Periotest instrument was able to identify non-integrated implants only when measured at Stage II surgery and 12 months after occlusal loading, 64% of the time. However, Periotest values recorded at Stage II surgery are not valid predictors of non-osseointegrated implants 12 months post-occlusal loading.
منابع مشابه
Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study
Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
متن کاملThe Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs
Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...
متن کاملEvaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study
Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...
متن کاملImplant-retained mandibular overdentures with Brånemark System MKII implants: a prospective comparative study between delayed and immediate loading.
This study was designed to compare the results of immediate and delayed loading of implants with implant-retained mandibular overdentures. Ten patients (test group) received 40 Brånemark System MKII implants (4 per patient) placed in the interforaminal area of the mandible. Standard abutments were immediately screwed to the implants, rigidly connected with a bar, and immediately loaded with an ...
متن کاملMobility assessment with the Periotest system in relation to histologic findings of oral implants.
The relationship between mobility assessment with the Periotest system and histologic findings was evaluated for oral implants. Five screw-type implants of pure titanium were placed in the mandibles of four monkeys. Two implants in each monkey were occlusally overloaded. These implants were brushed once a week. Plaque was allowed to accumulate around unloaded implants with abutments in the same...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2000