Transesophageal echocardiographic guidance of transcatheter closure of the aortic valve in a patient with left ventricular assist device-related severe aortic regurgitation

نویسندگان

  • Preetham R Muskala
  • Taiyeb M Khumri
  • Michael L Main
چکیده

A 68 year-old man with a severe ischemic cardiomyopathy underwent left ventricular assist device (LVAD) implantation (Heart Mate II device) for destination therapy. He presented 49 months following LVAD implant with worsening heart failure symptoms and new severe aortic regurgitation. Given high risk for both surgical and transcatheter aortic valve replacement, he was admitted for transcatheter closure of the aortic valve under transesophageal echocardiographic (TEE) guidance. TEE imaging revealed severe aortic regurgitation (see Figure 1A and 1B, and multimedia files 1 and 2). Under TEE and fluoroscopic guidance, a 25 mm Amplatzer cribiform atrial septal defect closure device was advanced across the aortic valve (see figures 1C and 1D, and multimedia files 3 and 4). Immediately following device deployment, TEE revealed a well-seated device with complete aortic valve closure, and trivial aortic regurgitation (see figures 2A-D, and multimedia files 5-7). Subsequent transthoracic echocardiograms obtained from 74 to 172 days post-procedure revealed no residual aortic regurgitation. The patient awoke with diffuse urticaria 244 days following the procedure, and died en route to the emergency department, presumably secondary to a systemic allergic reaction. De novo aortic regurgitation is increasingly recognized in patients with LVADs (1). TEE guided transcatheter aortic valve closure is an option in these high-risk patients (2).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Percutaneous transcatheter aortic valve closure successfully treats left ventricular assist device-associated aortic insufficiency and improves cardiac hemodynamics.

OBJECTIVES This study sought to assess the effectiveness of a novel percutaneous method to treat left ventricular assist device (LVAD)-associated severe aortic insufficiency (AI) in a series of patients determined to be poor reoperative candidates. BACKGROUND The increased use of continuous-flow LVAD in advanced heart failure has led to marked changes in the management of patients with this c...

متن کامل

Transcatheter closure of paravalvular defects using a purpose-specific occluder.

OBJECTIVES This study sought to describe a method of paravalvular leak closure using a purpose-specific occlusion device. BACKGROUND Transcatheter closure of paravalvular leaks has been hampered by technical challenges, the limitations of available imaging modalities, and the lack of closure devices specifically designed for this purpose. METHODS Patients with severe symptomatic paravalvula...

متن کامل

Transcatheter Valve-in-Valve implantation after late migration of balloon expandable Sapien-XT prosthesis in a severe pure aortic regurgitation case

A 76-year old female, was admitted in our cardiac surgery clinic to perform surgical aortic valve replacement due to a severe aortic regurgitation with symptoms of congestive heart failure. Her past medical history included moderately impaired renal function (GFR 48 mL/min) and arterial hypertension.  The thoracic-CT scan revealed a serious calcification of the entire thoracic aorta (Figure 1)...

متن کامل

Transcatheter aortic paravalvular leak closure using 3 Amplatzer Vascular Plug III devices in a child

Paravalvular leak (PVL) is usually related to disruption of prosthetic valve sewing ring sutures. Many previous reports have described transcatheter paravalvular leak closure in adult patients [1–4], but those describing such a procedure in children are scarce. A 16-year-old boy underwent an aortic valve replacement (AVR) with a stented bioprosthesis Hancock 23 mm due to combined aortic stenosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017