Estimation of the diameter and cross-sectional area of the internal jugular veins in adult patients

نویسندگان

  • Déborah Tartière
  • Philippe Seguin
  • Charlotte Juhel
  • Bruno Laviolle
  • Yannick Mallédant
چکیده

INTRODUCTION Unawareness of an asymmetry between the right and left internal jugular vein (IJV) and methodological pitfalls in previous studies raise concerns about such asymmetry. Hence the aim of this prospective non-interventional study was to validate the hypothesis that right IJV diameter is greater than those of left IJV and to determine the cross-sectional area of the IJVs using computed tomography (CT)-scans and original automatic software. METHODS All consecutive adult outpatients who underwent a thoracic contrast-enhanced (TCE) helical CT-scan during a 5-month period were included. To determine diameter and cross sectional area of the IJVs, we used Advanced Vessel Analysis software integrated in a CT-scan (Advanced Vessel Analysis on Advantage Workstation Windows 4.2; General Electrics) allowing automatic segmentation of vessels and calculation of their diameters and cross-sectional areas. RESULTS A total of 360 TCE CT-scans was performed; 170 were excluded from the analysis. On the remaining 190 CT scans, the diameter and cross-sectional area of the right IJV were significantly greater than those of the left IJV (17 +/- 5 mm [median: 17 mm, range: 13 to 20 mm] vs. 14 +/- 5 mm [median: 13 mm, range: 10 to 16 mm], P < 0.001; and 181 +/- 111 mm2 [median: 160 mm2, range: 108 to 235 mm2] vs. 120 +/- 81 mm2 [median: 102 mm2, range: 63 to 168 mm2], P < 0.001, respectively). CONCLUSIONS In a general population of adult outpatients, the diameter and cross-sectional area of the right IJV were significantly greater than those of the left IJV. This could be an additional argument to prefer right over left IJV cannulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EF FECTS OF THE VALSALVA MANEUVER AND HEAD ROTATION ON INTERNAL JUGULAR VEIN DIAMETER AND LOCATION BY ULTRASONOGRAPHY

In order to determine the effect of Valsalva maneuver and head rotation on the internal jugular vein (IJV) diameter and cross-sectional area and overlap with the carotid artery (CA) and find the best technique for safe cannulation of the IJV and decrease the risk of CA puncture, the diameter of both the IJV and the CA and percentage of overlap between the two vessels and cross-sectional are...

متن کامل

Author's response to reviews Title: Cross-sectional area variations of internal jugular veins during supine head rotation in multiple sclerosis patients with chronic cerebrospinal venous insufficiency: a prospective diagnostic controlled study with duplex ultrasound investigation Authors:

Title: Cross-sectional area variations of internal jugular veins during supine head rotation in multiple sclerosis patients with chronic cerebrospinal venous insufficiency: a prospective diagnostic controlled study with duplex ultrasound investigation Authors:

متن کامل

Sonographic Evaluation of Internal Jugular Vein Diameter and Cross-sectional Area Measurements in Correlation with Left Ventricular End Diastolic Area as a Tool for Perioperative Assessment of Volume Status in Pediatric Patients Undergoing Cardiac Surgery

AIM The aim of this study is to compare the ultrasound estimation of the cross-sectional area (CSA) and diameter of internal jugular vein (IJV) with left ventricular end diastolic area (LVEDA) for the assessment of intravascular volume in pediatric patients during cardiac surgery. PATIENTS AND METHODS The CSA and diameter of the left IJV were defined, using ultrasound machine, and compared wi...

متن کامل

Ultrasound assessment of the jugular and vertebral veins in healthy individuals: selected physiological aspects and morphological parameters

AIM Ultrasound assessment of morphological parameters of the internal jugular veins and vertebral veins in healthy individuals as well as their dependence on the patient's position. MATERIAL The examinations were conducted in 185 healthy individuals (101 females and 84 males) aged 18-89. Ultrasound examinations were conducted with the use of a linear probe with the frequency of 5-9 MHz in the...

متن کامل

Effect of Trendelenburg position on right and left internal jugular vein cross-sectional area

BACKGROUND Unlike the right internal jugular vein (RIJV), there is a paucity of data regarding the effect of the Trendelenburg position on the left internal jugular vein (LIJV). The purpose of this study is to investigate the cross-sectional area (CSA) of the LIJV and RIJV and their response to the Trendelenburg position using two-dimensional ultrasound in adult subjects. METHODS This study e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2009