The optical cell rotator.

نویسندگان

  • Moritz K Kreysing
  • Tobias Kiessling
  • Anatol Fritsch
  • Christian Dietrich
  • Jochen R Guck
  • Josef A Käs
چکیده

The optical cell rotator (OCR) is a modified dual-beam laser trap for the holding and controlled rotation of suspended dielectric microparticles, such as cells. In contrast to optical tweezers, OCR uses two counter-propagating divergent laser beams, which are shaped and delivered by optical fibers. The rotation of a trapped specimen is carried out by the rotation of a dual-mode fiber, emitting an asymmetric laser beam. Experiments were performed on human erythrocytes, promyelocytic leukemia cells (HL60), and cell clusters (MCF-7). Since OCR permits the rotation of cells around an axis perpendicular to the optical axis of any microscope and is fully decoupled from imaging optics, it could be a suitable and expedient tool for tomographic microscopy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of Rotator Cuff Repairs Revised to Shoulder Arthroplasty

Background: Successful repair of a torn rotator cuff may prevent progression to rotator cuff arthropathy. However,previous studies have shown a substantial rate of failure after rotator cuff repair and characteristics of surgicallyrepaired rotator cuffs that go on to shoulder arthroplasty have not been fully elucidated. The purpose of this study wasto determine the patient cha...

متن کامل

Imaging of the Rotator Cuff With Optical Coherence Tomography.

This study evaluated the utility of optical coherence tomography (OCT) in imaging porcine and human rotator cuff (RTC) tissue, analyzed its effectiveness in identifying clinical pathology, and correlated these findings with histologic examination. Twelve human cadaveric and 6 porcine shoulders were evaluated. Six-millimeter-wide bone sections were harvested from the proximal humerus of each spe...

متن کامل

Strength and Range of Motion of Internal and External Rotator Muscles in Volleyball Players With and Without Uneven Shoulders

Objective: Performing repetitive overhead movements puts stress on the shoulder joint, leading to uneven shoulders and pain in the shoulder joint. The purpose of this study was to evaluate and compare the strength and Range of Motion (ROM) of internal and external rotator muscles in volleyball players with and without uneven shoulders. Methods: This is a descriptive and causal-comparative stud...

متن کامل

Polarization splitter and polarization rotator designs based on transformation optics.

The transformation optics technique is employed in this paper to design two optical devices - a two-dimensional polarization splitter and a three-dimensional polarization rotator for propagating beams. The polarization splitter translates the TM- and the TE-polarized components of an incident beam in opposite directions (i.e., shifted up or shifted down). The polarization rotator rotates the po...

متن کامل

Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

 Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 16 21  شماره 

صفحات  -

تاریخ انتشار 2008