Calculation of aortic valve area by Doppler echocardiography: a direct application of the continuity equation.
نویسندگان
چکیده
The continuity equation suggests that a ratio of velocities at two different cardiac valves is inversely proportional to the ratio of cross-sectional areas of the valves. To determine whether a ratio of mitral/aortic valve orifice velocities is useful in determining aortic valve area in patients with aortic stenosis, 10 control subjects and 22 patients with predominant aortic stenosis were examined by Doppler echocardiography. The ratio of (mean diastolic mitral velocity)/(mean systolic aortic velocity), (Vm)/(Va), and the ratio of (mitral diastolic velocity-time integral)/(aortic systolic velocity-time integral), (VTm)/(VTa), were determined from Doppler spectral recordings. Aortic valve area determined at catheterization by the Gorlin equation was the standard of reference. High-quality Doppler recordings were obtained in 30 of 32 subjects (94%). Catheterization documented valve areas of 0.5 to 2.6 (mean 1.1) cm2. There was good correlation between Doppler-determined (Vm)/(Va) and Gorlin valve area (r = .90, SEE = 0.23 cm2); a better correlation was noted between (VTm)/(VTa) and Gorlin valve area (r = .93, SEE = 0.18 cm2). The data demonstrate the usefulness of Doppler alone in the determination of aortic valve area in adults with absent or mild aortic or mitral regurgitation and no mitral stenosis. Although the use of mean velocity and velocity-time integral ratios requires accurate measurement of mitral and aortic velocities, it does not require squaring of these velocities or measurement of the cross-sectional area of flow.
منابع مشابه
Doppler Assessment of Prosthetic Valve Orifice Area
Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...
متن کاملAssessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.
AIMS Two-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular outflow tract (LVOT) velocity and geometric assumptions of LVOT area, which can amplify error, especially in upper septal hypertrophy (USH). We hypothesized that real-time three-dimensional echocardiography (RT3DE) ca...
متن کاملDoppler assessment of prosthetic valve orifice area. An in vitro study.
BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...
متن کاملStenotic Aortic Valve Area
I n aortic stenosis, the aortic valve area (AVA) is intuitively the most appealing measure of severity because it is supposed to be (largely) independent of stroke volume and left ventricular pump function and reflects most closely “stenosis.” Calculation of the AVA by the continuity equation is routinely performed in echocardiography (1), using 3 measurements: the velocity-time integral of the...
متن کاملVALVULAR HEART DISEASE A hybrid approach for quantification of aortic valve stenosis using cardiac magnetic resonance imaging and echocardiography
Background. Doppler-derived calculation of aortic valve area (AVA) using the continuity equation can be difficult at times, e.g. due to poor acoustic windows, heavy calcification of the aortic valve, or significant flow acceleration in the left ventricular outflow tract. The aim of this study was to compare AVA as assessed by means of transthoracic echocardiography (TTE) with a hybrid approach,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 73 5 شماره
صفحات -
تاریخ انتشار 1986