Emergency EPR and OSL dosimetry with table vitamins and minerals.

نویسندگان

  • S Sholom
  • S W S McKeever
چکیده

Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EPR and OSL emergency dosimetry with teeth: A direct comparison of two techniques

The OSL dosimetry technique with teeth has been validated against the EPR dosimetry technique through a measurement comparison performed on the same teeth. The OSL reconstructed doses were found to be in agreement with corresponding EPR doses. Minimum measurable doses for the OSL technique were estimated to be in the range 0.9e1.5 Gy for measurements made within 24 h post-exposure if OSL signal...

متن کامل

Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

PURPOSE In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Re...

متن کامل

Retrospective dose assessment in a radiation mass casualty by EPR and OSL in mobile phones

In the retrospective dose assessment of individuals potentially exposed to ionizing radiation after an accident, dosimetry with inert materials can complement or be used as an alternative to biodosimetry assays. Dosimetry based on physical methods such as Electron Paramagnetic Resonance (EPR), Thermoluminescence (TL) or Optically Stimulated Luminescence (OSL) provides measurements of absorbed d...

متن کامل

Application of spectroscopic techniques in the radiation dosimetry of glasses: An update

The colorimetry and thermoluminescence properties of gamma irradiated glass were reported in as early as 1920. The utility of radio-photoluminescence (RPL) of silver activated metaphosphate glass for monitoring high doses of accidental and routine gamma radiation was reported in the 1960s. Since then considerable amount of research work has been carried out to study the thermoluminescence (TL),...

متن کامل

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 172 1-3  شماره 

صفحات  -

تاریخ انتشار 2016