The Bateman bipolar femoral head replacement. A fluoroscopic study of movement over a four-year period.
نویسنده
چکیده
The purpose of this study was to establish if the Bateman prosthesis functions as a bipolar device moving primarily at the inner metal-on-polyethylene bearing as originally proposed, or as a unipolar hemiarthroplasty moving at the outer metal-on-cartilage surface as has recently been suggested. One hundred hips were examined at one year follow-up; 78 were examined again at two to four years. The replacement was performed for arthritis in 76 hips and for femoral neck fracture in 24. Movement was assessed both with and without weight-bearing. In 80% of the arthritis group the prosthesis functioned as a bipolar hip replacement with movement occurring primarily at the inner metal-on-polyethylene surface. By contrast, in 75% of the fracture group the prosthesis functioned largely as a unipolar device with movement occurring primarily at the outer metal-on-cartilage surface. In all cases examined serially the movement pattern was the same at two to four years as it has been at one year. Clearly, the action of the prosthesis depends on the condition of the acetabular cartilage.
منابع مشابه
A dislocation of the inner head in bipolar prosthesis with a self-centering system: a case report.
We present a case of inner head dislocation 11 years after the replacement of a bipolar prosthesis with a self-centering system. An 84-year-old woman with osteoarthritis of the left hip underwent a replacement of the Bateman UPF-II bipolar prosthesis in 1987. She fell off a chair on April 19 1998, and felt a sudden sharp pain in the left hip. Roentgenograms revealed that the inner head was disl...
متن کاملBipolar versus fixed-head hip arthroplasty for femoral neck fractures in elderly patients
Between 2002 and 2007, fifty elderly patients with displaced femoral neck fractures were treated with hip replacement at Emergency Hospital, Mansoura University. Patients were randomly selected, 25 patients had either cemented or cementless bipolar prosthesis, and another 25 patients had either cemented or cementless fixed-head prosthesis. There were 34 women and 16 men with an average age of 6...
متن کاملNot-Approved Weight Gain Supplements as a Cause of AVN: A Cautionary Report
Introduction: Avascular necrosis (AVN) of the femoral head is a leading cause of end-stage joint disease in the young population that can conduct patients to total hip replacement in early life. There are various risk factors including, trauma, corticosteroids, thrombosis, hypertension, and alcohol. There is a growing number of femoral head AVN patients with a history of self-medication with he...
متن کاملBipolar or unipolar hemiarthroplasty after femoral neck fracture in the geriatric population.
BACKGROUND The choice of prosthesis in hemiarthroplasty is controversial for geriatric patients after femoral neck fracture. We hypothesised that selection criteria for unipolar or bipolar prostheses could be constructed based on factors affecting mortality. AIMS THE AIMS OF THIS RETROSPECTIVE STUDY WERE: (1) to determine the factors affecting mortality of femoral neck fracture patients ≥65 y...
متن کاملOpen Anterior Hip Dislocation in A Child: A Rare Mechanism of Injury
Traumatic anterior dislocation of the hip is an extremely rare condition in children and open dislocation is even rarer. Thisisusually caused by high-energy trauma. In the current study, we present a case of an eight-year-old child suffering froman open anterior–inferior dislocation of the right hip concomitant with pelvic ring disruption and an ipsilateral open distalfemoral fracture (Salter-H...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 69 5 شماره
صفحات -
تاریخ انتشار 1987