Combined influence of ventricular loading and relaxation on the transmitral flow velocity profile in dogs measured by Doppler echocardiography.
نویسندگان
چکیده
The relation of the Doppler transmitral flow velocity profile to left ventricular loading conditions and diastolic properties remains poorly described. We studied seven adult mongrel dogs with an open-chest right heart bypass model in which left atrial pressure, representing preload, was varied by controlling blood flow into the pulmonary artery and left ventricular systolic pressure, representing afterload, was controlled independently by pumping blood into or from the femoral arteries. Heart rate was kept constant by crushing the sinus node and pacing the right atrium. Mitral inflow velocity profiles were measured by pulsed-wave Doppler echocardiography at multiple left atrial and left ventricular systolic pressures. In individual dogs, the peak E-wave velocity increased linearly with increasing left atrial V-wave pressure at constant left ventricular systolic pressure and decreased with increasing left ventricular systolic pressure at constant left atrial pressure. Stepwise multiple linear regression analysis of data pooled from all experimental stages in all dogs identified left atrial V-wave pressure, the time constant of relaxation (TL), and left ventricular systolic pressure, in order of decreasing significance, as predictors of the peak E-wave velocity (n = 82, multiple r = 0.87, p less than 0.0001). Multivariate analysis with the same three factors in individual dogs yielded higher r values (mean r = 0.89; range, 0.85-0.97), suggesting the presence of important interdog differences that were not accounted for by these three factors alone. When the values of codeterminant hemodynamic factors were kept within narrower limits, correlations between peak E-wave velocity and left atrial V-wave pressure (n = 35, multiple r = 0.83, p less than 0.0001), TL (n = 76, multiple r = -0.54, p less than 0.0001) and left ventricular systolic pressure (n = 20, multiple r = -0.59, p less than 0.005) improved substantially. In the pooled data, the relation of the peak E-wave velocity to left atrial V-wave pressure was shifted downward by an increase in TL (reduced relaxation rate), and the relation of the peak E-wave velocity to TL was shifted upward by an increase in left atrial V-wave pressure. Multivariate analysis also selected left atrial V-wave pressure and TL as the two most significant correlates of the velocity-time integral and deceleration rate of the E wave.(ABSTRACT TRUNCATED AT 400 WORDS)
منابع مشابه
Diastolic Function and Dysfunction the Echo-doppler Evaluation of Left Ventricular Diastolic Function
7. Appleton CP, Hatle LK: The natural history of left ventricular filling abnormalities: Assessment by two-dimensional and Doppler echocardiography. Echocardiography 9:437-457, 1992 8. Appleton CP, Hatle LK, Popp RL: Cardiac tamponade and pericardial effusion: Respiratory variation in transvalvular flow velocities studied by Doppler echocardiography. J Am Coll Cardiol 11:1020-1030, 1988 Abstrac...
متن کاملThe influence of Asthma on Right Ventricular Systolic and Diastolic Function in Children according to Tissue Doppler Echocardiography
Introduction:Asthma is the most common chronic inflammatory condition affecting the lower airways among children. Asthma may influence right ventricular (RV) function and patients may develop right ventricular hypertrophy, pulmonary hypertension and cor pulmonale. The main objective of this study is to determine RV dysfunction in asymptomatic asthmatic children as detected by ti...
متن کاملEchocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs
Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...
متن کاملAssessment of left ventricular relaxation by Doppler echocardiography. Comparison of isovolumic relaxation time and transmitral flow velocities with time constant of isovolumic relaxation.
Isovolumic relaxation time (IVRT) and events of early transmitral flow measured by Doppler echocardiography were validated against the time constant of left ventricular relaxation (tau) in open-chest dogs. During increased inotropy (by isoproterenol infusion) at constant preload, enhancement of relaxation was indicated by a decrease in tau from 48 +/- 12 (mean +/- SD) to 33 +/- 5 msec (p = 0.04...
متن کاملMeasurement of aortic regurgitation by Doppler echocardiography.
In an attempt to develop a new approach to the non-invasive measurement of aortic regurgitation, transmitral volumetric flow (MF) and left ventricular total stroke volume (SV) were measured by Doppler and cross sectional echocardiography in 23 patients without aortic valve disease (group A) and in 26 patients with aortic regurgitation (group B). The transmitral volumetric flow was obtained by m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 78 3 شماره
صفحات -
تاریخ انتشار 1988