New quantitative parameters on a recently introduced automated blood cell counter--the XE 2100.

نویسندگان

  • C Briggs
  • P Harrison
  • D Grant
  • J Staves
  • S J MacHin
چکیده

The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count was highly correlated (r = 0.97) with the manual reference count. For counts below 100 x 109/l the 'optical' method and the immunocount gave good a correlation (r = 0.97) optical and impedance counts were also well correlated (r = 0.89). The use of the 'optical' platelet count significantly improves the reliability of low platelet counts. The IG count correlated with visual counts (r = 0.81) and allows the detection of immature cells at an earlier stage in the laboratory process. The introduction of fluorescent flow cytometric analysis allows extended quantification of additional cell populations and so potentially improves screening and monitoring of various pathological conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First basic performance evaluation of the XE-2100 haematology analyser

The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2K. Reproducibility, carryover, sta...

متن کامل

The New Sysmex XN-2000 Automated Blood Cell Analyzer More Accurately Measures the Absolute Number and the Proportion of Hematopoietic Stem and Progenitor Cells Than XE-2100 When Compared to Flow Cytometric Enumeration of CD34+ Cells

The gold standard to count circulating hematopoietic stem and progenitor cells (HPCs) is to enumerate CD34 cells by using flow cytometry [1, 2]. XE-2100 (Sysmex, Kobe, Japan), a currently used hematology analyzer, can be used to quantify HPCs, generating counts that reportedly correlate with those obtained using flow cytometric analysis of CD34 cells; however, XE-2100 HPC counts were 1.86-fold ...

متن کامل

Automated Bone Marrow Analysis : Dream or Reality?

Since 1997, the availability, in haematology laboratories of automated analyzers capable of performing an extended differential blood cell count, including the nucleated red blood cell (NRBC) count, allowed their experimental use to estimate the cell composition of bone marrow fluid. In 1999 we evaluated the Sysmex XE-2100 to detect the clinical usefulness of immature granulocyte (IG) and NRBC ...

متن کامل

Automated counting of nucleated red blood cells in blood samples of newborns.

Nucleated red blood cells (NRBC) in blood samples interfere with the white blood cell (WBC) count on many types of automated haematology analysers. This makes it necessary to correct the WBC count by counting NRBC microscopically. This report describes the evaluation of two analysers, the Cell-Dyn 4000 and the Sysmex XE-2100, which use new techniques to recognize and enumerate NRBC. We conclude...

متن کامل

Performance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.

Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and laboratory haematology

دوره 22 6  شماره 

صفحات  -