Tubular vs Profile Plate in Peroneal or Bimalleolar Fractures: is There a Real Difference in Skin Complication? A Retrospective Study in Three Level I Trauma Center

نویسندگان

  • Rosario Petruccelli
  • Michele Bisaccia
  • Giuseppe Rinonapoli
  • Giuseppe Rollo
  • Luigi Meccariello
  • Gabriele Falzarano
  • Paolo Ceccarini
  • Olga Bisaccia
  • Marco Giaracuni
  • Auro Caraffa
چکیده

INTRODUCTION Not enough literature is available to evalute the wound complication rate of plates type in distal fibular fractures. AIM The aim of our study was to compare wound complications of using a third tubular plate compared to LCP distal fibula plate. MATERIAL AND METHODS This study is a retrospective single-centre study in which was performed plating of fibula in closed ankle fractures. 93 patients were included in our study and assigned in two groups, based on using of different implant : in group A 48 patients were treated with one-third tubular and in group B 45 patients were treated with LCP distal fibula plate. There were no significant differences in the baseline characterisctics. Patients received the same surgical procedure and the same post-operative care, then they were radiologically evalueted at 1-3-12 months and clinical examination was made at 12 months using AOFAS clinical rating system. Categorical data, grouped into distinct categories, were evalueted using Chi-square test. We considered a p value < 0.05 as statistically significant. RESULTS The wound complications rate of the overall study group was 7.6%. There were no statistical differences in the rate of wound complications between the two groups. There were no differences between both group in percentage of hardware removal at follow-up (overall 5.4%); plate removal was performed earlier in the locking plate because of wound complications. CONCLUSIONS Our study has shown no difference in radiographic bone union rate, no significant differences in terms of clinical outcomes, in time of bone reduction and wound complication rate between the LCP distal fibula plate and conventional one-third tubular plate. Controversy still exists about the best method for the fracture reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Much are Emergency Medicine Specialists’ Decisions Reliable in the Diagnosis and Treatment of Pediatric Fractures?

  Background: Considering the importance of an early diagnosis and proper decision-making in regards to the treatment of pediatric distal radius and elbow fractures, this study examines emergency medicine specialists’ accuracy in the diagnosis and treatment of these patients. Methods: From 2012 and 2013, children less than 14 years old who were referred to an academic hospital emergency departm...

متن کامل

Case-Match Controlled Comparison of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing for the Stabilization of Humeral Shaft Fractures.

OBJECTIVES To compare the risk of major complications after either minimally invasive plate osteosynthesis (MIPO) or intramedullary nailing (IMN) of humeral shaft fractures. DESIGN Retrospective, case-match controlled study. SETTING A major metropolitan tertiary referral trauma center in Australia. PATIENTS Thirty patients with fractures of the humeral shaft. INTERVENTION Either MIPO or...

متن کامل

Long-term Outcomes after Primary Radial Head Resection Arthroplasty vs. Acute Radial Head Resection vs. Secondary Prosthetic Removal in Comminuted Radial Head Fractures

Background: Aim of this study was to compare the clinical and radiological long-term outcomes following operativetreatment of comminuted radial head fractures using 1) primary radial head resection arthroplasty, 2) acute radial headresection, or 3) necessary secondary prosthetic removal. Additionally, we evaluated complex radial head fracturescombined with elbow dislocation and verified the hyp...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Repairing angle of the mandible fractures with a strut plate.

IMPORTANCE Despite multiple fixation techniques, the optimal method of repairing mandibular angle fractures remains controversial. OBJECTIVE To evaluate the outcomes when using a 3-dimensional, curved strut plate in repair of angle of the mandible fractures. DESIGN Retrospective cohort study. SETTING Level I trauma center at an academic institution in Harris County, Texas. PARTICIPANTS ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 71  شماره 

صفحات  -

تاریخ انتشار 2017