Comparison of Vitek and Cobas Micro systems with a semiautomated conventional microsystem for identification and susceptibility testing of gram negative bacilli.
نویسندگان
چکیده
AIMS To compare the sensitivity and specificity of two semiautomated systems against a conventional (MIC 2000) test system for the identification and antibiotic susceptibility of Gram negative bacteria. METHODS Clinical isolates of Gram negative bacilli (188 urinary and 229 non-urinary strains) were identified and tested for antibiotic susceptibility in the Cobas Micro and MIC 2000 systems. Of these, 359 strains were then tested in the Vitek and MIC 2000 systems. Two hundred and forty three strains were tested in all three systems immediately after isolation. Forty three were also tested only in the Vitek and MIC 2000 systems immediately after isolation. The remaining 174 strains were tested after storage at -20 degrees C for several months. RESULTS The Cobas Micro and MIC 2000 systems agreed on the identification of 310 of the 417 (74.3%) strains; the Vitek and MIC 2000 systems agreed on 338 of the 359 (94.2%) strains. The Cobas Micro system correctly identified 86.8% of strains tested after storage and 65.4% of those immediately after isolation. Organism-antibiotic combinations (non-urinary isolates) were tested in the Cobas Micro and MIC 2000 systems (n = 2335), in the Vitek and MIC 2000 systems (n = 999). Essential correlation (complete agreement plus minor errors) was observed in 98% (with 90% complete agreement) in the former and in 97% (with 86% complete agreement) in the latter. For the urinary isolates, 1949 organism-antibiotic combinations were analysed in the Cobas Micro and MIC 2000 systems where complete agreement was observed in 92% (with 3% very major discrepancies), for 1382 urinary organism-antibiotic combinations tested in the Vitek and MIC 2000 systems, the figures were 95% and 2%, respectively. CONCLUSIONS The Vitek system is highly accurate in the identification and antibiotic susceptibility testing of Gram negative bacteria. The Cobas Micro system has many shortcomings in its identification of Gram negative rods, especially freshly isolated strains, but it is comparable with the Vitek system in antibiotic susceptibility testing.
منابع مشابه
Prevalence of Drug Resistance in Nonfermenter Gram-Negative Bacilli
Background and Objectives: Non-fementer gram-negative bacilli (NFGB) are ubiquitous pathogen that has emerged as a major cause of health care associated infections. The aim of this study was to determine the prevalence and antimicrobial susceptibility of NFGB in an Iranian hospital. Materials and Methods: FromJuly 2005 to November 2006 a total of 257 strains of NFGB including 109 (42.41%)...
متن کاملRapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT/ALERT blood cultures.
BACKGROUND AND PURPOSE In order to reduce the turnaround time for laboratory diagnosis of bacteremia, the efficacy of identification and antimicrobial susceptibility testing using samples taken directly from positive BacT/ALERT standard aerobic and standard anaerobic blood culture bottles was evaluated. METHODS 160 positive blood culture bottles were examined and incubated at 35 degrees C in ...
متن کاملAccuracy of the VITEK® 2 system for a rapid and direct identification and susceptibility testing of Gramnegative rods and Gram-positive cocci in blood samples.
The performance of the VITEK® 2 system for direct rapid identification and antimicrobial susceptibility testing of the bacteria responsible for blood infections was determined. The isolates studied included 166 Gram-negative rods and 74 Gram-positive cocci from inpatients. Specially treated monomicrobial samples from positive blood culture bottles were directly inoculated into the VITEK 2 syste...
متن کاملEvaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures.
This study explores the possibility of combining the BacT/Alert Microbial Detection System with the VITEK 2 system to achieve rapid bacterial identification and susceptibility testing. Direct inoculation of bacterial suspension to the VITEK 2 ID-GNB card and AST-NO09 card was made by differential centrifugation of blood cultures of organisms with gram-negative enteric bacillus-like morphology. ...
متن کاملCritical evaluation of the AutoMicrobic system gram-negative identification card for identification of glucose-nonfermenting gram-negative rods.
During a 6-month study we critically evaluated the accuracy of the AutoMicrobic system Gram-Negative Identification Card (Vitek Systems, Inc., Hazelwood, Mo.) in identifying glucose-nonfermenting gram-negative bacilli by testing 419 selected isolates in parallel with a conventional reference method. Of 356 isolates included in the AutoMicrobic system profile, a total of 307 (86.2%) were correct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 47 1 شماره
صفحات -
تاریخ انتشار 1994