Validation of a new fiber electrode prototype for clinical electroretinography.
نویسندگان
چکیده
PURPOSE To validate a new fiber electrode prototype for clinical electroretinography (ERG). METHODS A recently developed prototype of a disposable reference-coupled fiber electrode (patent pending Brazilian Institute of Industrial Property # PI0602186-7), including one fiber for corneal signals and a second fiber acting as reference was tested in a group of 20 healthy volunteers (17-31 years; mean 22.7 +/- 4.5; 8 males). Standard electroretinography rod and cone responses were recorded from a fully dilated pupil simultaneously in both eyes with a reference-coupled fiber electrode prototype in one randomly assigned eye and a DTL electrode in the other eye after 30 min of dark-adaptation. After presenting dark- and light-adapted stimuli, each response was analyzed for a- and b-wave amplitude and implicit time. The VERIS 5.1.9 system was used for electroretinography data acquisition and analysis. Electroretinography outcomes were analyzed by Mann-Whitney test. Slit-lamp examination was performed in both eyes right after electroretinography session to evaluate possible adverse effects. RESULTS Responses recorded with reference-coupled fiber electrode prototypes were comparable to commercially available DTL fiber electrodes. On a qualitative analysis, reference-coupled fiber electrodes provided recordings with less amount of noise. On average, scotopic electroretinography amplitude and b-wave implicit time recorded using DTL were, respectively, 287.6 microV and 36.3 ms with similar findings for the reference-coupled fiber electrode prototype (287.9 microV and 36.3 ms). Under photopic conditions DTL mean amplitude and implicit time were, respectively 108.9 microV and 24.5 ms with similar results for the reference-coupled fiber electrodes prototypes (116.4 microV and 24.5 ms). No corneal abrasions or any other significant adverse effects were found after electroretinography recording with both electrodes. CONCLUSIONS The reference-coupled fiber electrode prototype provided stable and safe recordings of corneal electroretinograms compared to the commercially availabe DTL electrode in healthy human subjects. The prototype is a feasible alternative instrument for clinical electroretinography recording to assess retinal function, however further analysis is recommended to validate its clinical usefulness in patients with retinal disorders.
منابع مشابه
Electroretinography in dogs using a fiber electrode prototype
We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and...
متن کاملNon-invasive electroretinography.
Electroretinographic (ERG) investigations are conventionally performed by using corneal or conjunctival recording electrodes. Both types have to be placed in contact with the eye, resulting invasive and providing discomfort for the patient. This paper presents a simple technique to detect ERG potentials non-invasively. It relies on the use of a conducting liquid between the eye and an external ...
متن کاملDevelopment of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design
In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...
متن کاملCost Effective and Scalable Synthesis of MnO2 Doped Graphene in a Carbon Fiber/PVA: Superior Nanocomposite for High Performance Flexible Supercapacitors
In the current study, we report new flexible, free standing and high performance electrodes for electrochemical supercapacitors developed througha scalable but simple and efficient approach. Highly porous structures based on carbon fiber and poly (vinyl alcohol) (PVA) were used as a pattern. The electrochemical performances of Carbon fiber/GO-MnO2/CNT supercapacitors were characteriz...
متن کاملDisposable single-use electrochemical sensor: A novel hollow fiber based tool for environmental monitoring of cadmium
The objective of this study is to design a simple, fast, sensitive and single-use electrode with the simultaneous capability of preconcentration and measuring, for application in a three-electrode voltammetry system to identify and measure the heavy metal cadmium. The design process of this sensor consists of several stages. The polyurethane foam and multi walled carbon nanotubes nanoparticles ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 71 3 شماره
صفحات -
تاریخ انتشار 2008