A technique to measure the ability of the human nose to warm and humidify air.

نویسندگان

  • P Rouadi
  • F M Baroody
  • D Abbott
  • E Naureckas
  • J Solway
  • R M Naclerio
چکیده

To assess the ability of the nose to warm and humidify inhaled air, we developed a nasopharyngeal probe and measured the temperature and humidity of air exiting the nasal cavity. We delivered cold, dry air (19-1 degrees C, <10% relative humidity) or hot, humid air (37 degrees C, >90% relative humidity) to the nose via a nasal mask at flow rates of 5, 10, and 20 l/min. We used a water gradient across the nose (water content in nasopharynx minus water content of delivered air) to assess nasal function. We studied the characteristics of nasal air conditioning in 22 asymptomatic, seasonally allergic subjects (out of their allergy season) and 11 nonallergic normal subjects. Inhalation of hot, humid air at increasingly higher flow rates had little effect on both the relative humidity and the temperature of air in the nasopharynx. In both groups, increasing the flow of cold, dry air lowered both the temperature and the water content of the inspired air measured in the nasopharynx, although the relative humidity remained at 100%. Water gradient values obtained during cold dry air challenges on separate days showed reproducibility in both allergic and nonallergic subjects. After exposure to cold, dry air, the water gradient was significantly lower in allergic than in nonallergic subjects (1,430 +/- 45 vs. 1,718 +/- 141 mg; P = 0.02), suggesting an impairment in their ability to warm and humidify inhaled air.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alpha-adrenoreceptor blockade with phenoxybenzamine does not affect the ability of the nose to condition air.

The primary function of the nose is to warm and humidify air. We have previously shown that raising nasal mucosal temperature by immersing feet in warm water increases the amount of water evaporated by the nose as air passes through it (nasal conditioning capacity; Abbott D, Baroody F, Naureckas E, and Naclerio R. Am J Rhinol 15: 41-45, 2001). To investigate further the effect of nasal mucosal ...

متن کامل

Observations on the ability of the nose to warm and humidify inspired air.

The major function of the nose is to warm and humidify air before it reaches to the lungs for gas exchange. Conditioning of inspired air is achieved through evaporation of water from the epithelial surface. The continuous need to condition air leads to a hyperosmolar environment on the surface of the epithelium. As ventilation increases, the hyperosmolar surface moves more distally, covering a ...

متن کامل

-Adrenoreceptor blockade with phenoxybenzamine does not affect the ability of the nose to condition air

Pinto, Jayant M., Paraya Assanasen, Fuad M. Baroody, Edward Naureckas, and Robert M. Naclerio. -Adrenoreceptor blockade with phenoxybenzamine does not affect the ability of the nose to condition air. J Appl Physiol 99: 128–133, 2005. First published March 3, 2005; doi:10.1152/japplphysiol.00857.2004.—The primary function of the nose is to warm and humidify air. We have previously shown that rai...

متن کامل

Supine position decreases the ability of the nose to warm and humidify air.

We tested the hypothesis that decreasing nasal air volume (i.e., increasing nasal turbinate blood volume) improves nasal air conditioning. We performed a randomized, two-way crossover study on the conditioning capacity of the nose in six healthy subjects in the supine and upright position. Cold, dry air (CDA) was delivered to the nose via a nasal mask, and the temperature and humidity of air we...

متن کامل

Evaluating the mental and emotional effects of Sahand Bonab thermal power plant greenhouse on rural communities, Case study: Rurlas in Bonab

The increased use of thermal power plants has led to the spread of greenhouse gases in the air and has caused psychological problems for humans. Accordingly, the present study was conducted to measure the pollutants released by Sahand Bonab thermal power plant and to investigate the effects of this pollution on the psychological and psychological pressure of rural residents. The GWP100 method w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 1999