Noninvasive Dosimetry and Monitoring of TTT Using Spectral Imaging

نویسندگان

  • G. Schuele
  • F. E. Molnar
  • D. Yellachich
  • E. Vitkin
  • L. T. Perelman
  • D. Palanker
چکیده

Transpupillary thermo therapy (TTT) is a slow (60 seconds) photothermal treatment of the fundus with a near-infrared (780-810nm) laser irradiating a large spot (0.51. mm) on the retina. Due to high variability in ocular tissue properties and the lack of immediately observable outcome of the therapy, a real-time dosimetry is highly desirable. We found that fundus spectroscopy and spectrally-resolved imaging allow for non-invasive real-time monitoring and dosimetry of TTT. A 795nm laser was applied in rabbit eyes for 60 seconds using a 0.86mm retinal spot diameter. The fundus was illuminated with a broadband polarized light, and its reflectance spectra were measured in parallel and crosspolarizations. The fundus was also imaged in selected spectral domains. At irradiances that do not create ophthalmoscopically visible lesions the fundus reflectance increases at the wavelengths corresponding to absorption of the oxygenated blood indicating the reduced concentration of blood in the choroid. Vasoconstrictive response of the choroidal and retinal vasculature during TTT was also directly observed using spectrally-resolved imaging. At irradiances that produce ophthalmoscopically visible lesions a rapid reduction of the fundus reflectance was observed within the first 5-10 seconds of the exposure even when the visible lesions developed only by the end of the 60 second exposure. No visible lesions were produced where the laser was terminated after detection of the reduced scattering but prior to appearance of the enhanced scattering.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive technique for monitoring chorioretinal temperature during transpupillary thermotherapy, with a thermosensitive liposome.

PURPOSE To develop a technique for noninvasive and real-time monitoring of chorioretinal temperature in transpupillary thermotherapy (TTT). METHOD A modified slit lamp, which was equipped with two laser wavelengths (490 nm for illumination and fluorescein excitation and 810 nm for hyperthermia), was developed for TTT and temperature monitoring. Five types of liposomes were prepared, and their...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Noninvasive vascular imaging in fluorescent tumors using multispectral unmixing.

Noninvasive imaging of tumor vascularization in animal models provides an important tool for studying the biology of tumor angiogenesis as well as monitoring the effects of antiangiogenic therapies. Through the use of in vivo multispectral fluorescent imaging, we have discovered a distinct spectral signature associated with blood vessels present in fluorescent tumors in mice. This unique spectr...

متن کامل

Patient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods

Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...

متن کامل

Spectral Estimation of Printed Colors Using a Scanner, Conventional Color Filters and applying backpropagation Neural Network

Reconstruction the spectral data of color samples using conventional color devices such as a digital camera or scanner is always of interest. Nowadays, multispectral imaging has introduced a feasible method to estimate the spectral reflectance of the images utilizing more than three-channel imaging. The goal of this study is to spectrally characterize a color scanner using a set of conventional...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006