Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism

نویسندگان

  • Kimiya Shimizu
  • Kazutaka Kamiya
  • Akihito Igarashi
  • Hidenaga Kobashi
چکیده

UNLABELLED The study shows a promising next-generation surgical option for the correction of moderate to high ametropia. Hole implantable collamer lens (ICL), STAAR Surgical, is a posterior chamber phakic intraocular lens with a central artificial hole. As yet, however, no long-term comparison of the clinical results of the implantation of ICLs with and without such a hole has hitherto been conducted. A prospective, randomized, controlled trial was carried out in order to compare the long-term clinical outcomes of the implantation, in such eyes, of ICLs with and without a central artificial hole.Examinations were conducted of the 64 eyes of 32 consecutive patients with spherical equivalents of -7.53 ± 2.39 diopters (D) (mean ± standard deviation) in whom implantation of a Hole ICL was performed in 1 eye, and that of a conventional ICL was carried out in the other, by randomized assignment. Before 1, 3, and 6 months, and 1, 3, and 5 years after surgery, the safety, efficacy, predictability, stability, intraocular pressure, endothelial cell density, and adverse events of the 2 surgical techniques were assessed and compared over time.The measurements of LogMAR uncorrected and corrected distance visual acuity 5 years postoperatively were -0.17 ± 0.14 and -0.24 ± 0.08 in the Hole ICL group, and -0.16 ± 0.10 and -0.25 ± 0.08 in the conventional ICL group. In these 2 groups, 96% and 100% of eyes, respectively, were within 1.0 D of the targeted correction 5 years postoperatively. Manifest refraction changed by -0.17 ± 0.41 D and -0.10 ± 0.26 D occurred in from 1 month to 5 years in the Hole and conventional ICL groups, respectively. Only 1 eye (3.1%), which was in the conventional ICL group, developed an asymptomatic anterior subcapsular cataract.Both Hole and conventional ICLs corrected of ametropia successfully throughout the 5-year observation period. It appears likely that the presence of the central hole does not significantly affect these visual and refractive outcomes. TRIAL REGISTRATION UMIN000018771.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Optical Quality and Intraocular Scattering after Posterior Chamber Phakic Intraocular Lens with and without a Central Hole (Hole ICL and Conventional ICL) Implantation Using the Double-Pass Instrument

PURPOSE To objectively compare the optical quality and the intraocular scattering after implantation of the posterior chamber phakic implantable collamer lens (Visian ICL™, STAAR Surgical) with and without a central artificial hole for moderate to high ametropia. METHODS This retrospective study comprised 28 eyes of 28 consecutive patients undergoing Hole ICL implantation (mean age ± standard...

متن کامل

Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia.

AIM To assess the early clinical outcomes of an ICL with a central hole (Hole ICL) implantation for the correction of moderate to high myopia. METHODS This study evaluated 20 eyes of 20 patients with spherical equivalents of -7.36 ± 2.13 D (mean ± SD) who underwent Hole ICL implantation. Before surgery and at 1 week and 1, 3 and 6 months after surgery, we assessed the safety, efficacy, predic...

متن کامل

Ring-shaped dysphotopsia associated with posterior chamber phakic implantable collamer lenses with a central hole.

PURPOSE To evaluate the incidence of central hole-induced ring-shaped dysphotopsia after posterior chamber phakic implantable collamer lens (ICL) with central hole (hole ICL) implantation and to investigate the causes of central hole-induced dysphotopsia. METHODS The clinical study enrolled 29 eyes of 15 consecutive myopic patients implanted with hole ICL. The incidence of ring-shaped dysphot...

متن کامل

Three-Year Follow-Up of Posterior Chamber Toric Phakic Intraocular Lens Implantation for Moderate to High Myopic Astigmatism

PURPOSE To assess the 3-year clinical outcomes of toric phakic intraocular lens (Visian ICL™; STAAR Surgical) implantation for moderate to high myopic astigmatism. METHODS This retrospective study evaluated fifty eyes of 28 patients who underwent toric ICL implantation for the correction of moderate to high myopic astigmatism and who regularly returned for postoperative examination. Before, a...

متن کامل

Comparison between toric and spherical phakic intraocular lenses combined with astigmatic keratotomy for high myopic astigmatism

BACKGROUND To compare the outcomes of a toric phakic intraocular lens (PIOL) and a spherical PIOL combined with astigmatic keratotomy (AK) for the correction of high myopic astigmatism. METHODS This study enrolled patients with high myopic astigmatism, including 30 eyes (22 patients) that received a toric PIOL implantation (TICL group), and 32 eyes (24 patients) that received combined AK and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016