Reverse perfusion pattern in myocardial perfusion imaging using technetium-99m-sestamibi in patients with intermediate risk for coronary artery disease in relation to the time of acquisition and intensity of visceral uptake as artifactual causes.

نویسندگان

  • Babak Fallahi
  • Davood Beiki
  • Yalda Salehi
  • Alireza Emami-Ardekani
  • Armaghan Fard-Esfahani
  • Farahnaz Aghahosseini
  • Mahdi Haghighatafshar
  • Mohammad Eftekhari
چکیده

OBJECTIVE With respect to the equivocal value of the reverse perfusion pattern (RPP) in technetium-99m (Tc)-sestamibi myocardial perfusion imaging, a study was carried out to evaluate this pattern in association with the presence or absence of coronary artery disease (CAD) and other underlying factors, mainly the time of acquisition and the presence of intense visceral uptake. PATIENTS AND METHODS We prospectively studied 102 patients with a moderate risk of CAD (41 men and 61 women, mean age: 56.5±9.2 years) without a previous history of documented CAD, myocardial infarction, or revascularization. Myocardial perfusion imaging was performed using a 2-day dual-phase protocol with the stress and rest images, each obtained 15, 120, and 180 min after an injection of 666-814 MBq Tc-MIBI. According to the time of image acquisition, the following five protocols were defined, A: 15/15 min, B: 15/180 min, C: 180/180 min, D: 180/15 min, and E: 120/120 min for stress/rest images, respectively. RESULTS The odds of RPP were higher in the cases with more intense infradiaphragmatic visceral uptake on rest-phase images of the protocols A and D (odds ratios=1.2-7.8 and 1.2-7.5, respectively). Our results showed that RPP is related to incorrect normalization. Also, diabetes, sex, and CAD did not correlate with RPP. CONCLUSION This study found no relationship between RPP and CAD, diabetes mellitus, and sex; however, an association was found between RPP and incorrect normalization because of the variation of visceral uptake intensity in relation to the time of acquisition at stress and rest phases favoring the artifactual base of this pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria.  Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...

متن کامل

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

HIV-associated lymphocytic interstitial pneumonitis causes diffuse sestamibi lung uptake in myocardial perfusion imaging

Technetium-99m ((99m)Tc) sestamibi myocardial perfusion scintigraphy (MPI) is widely used for the diagnosis and assessment of prognosis in patients with suspected coronary artery disease. During these investigations, inspection of raw projected data for the purpose of quality control may occasionally yield incidental noncardiac findings that suggest the presence of another primary noncardiac di...

متن کامل

Artifactual reverse distribution pattern in myocardial perfusion SPECT with technetium-99m sestamibi.

BACKGROUND The reverse distribution pattern (RDP), in which resting perfusion imaging demonstrates a de novo or more marked regional defect than that present in stress images, is observed frequently in patients with a low likelihood of coronary artery disease. METHODS AND RESULTS To determine whether this scan pattern is artifactual and to investigate its causes, we retrospectively evaluated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine communications

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2017