Identification and location of a cysteinyl posttranslational modification in an amyloidogenic kappa1 light chain protein by electrospray ionization and matrix-assisted laser desorption/ionization mass spectrometry.

نویسندگان

  • A Lim
  • J Wally
  • M T Walsh
  • M Skinner
  • C E Costello
چکیده

Amyloid-deposited light chain (AL) amyloidosis is correlated with the overproduction of a monoclonal immunoglobulin light chain protein by a B-lymphocyte clone. Since the amyloid fibril deposits in AL amyloidosis most often consist of the N-terminal fragments of the light chain, the majority of studies have focused on the determination of the primary structure of the protein, and reducing agents have been used routinely in the initial purification process. In this study, two light chain proteins were isolated and purified, without reduction, from the urine of a patient diagnosed with kappa 1 (kappa1) AL amyloidosis. One protein had a relative molecular mass of 12,000 and the other 24,000. Electrospray ionization and matrix-assisted laser desorption/ionization mass spectrometry, in combination with enzymatic digestions, were used to verify the amino acid sequences and identify and locate posttranslational modifications in these proteins. The 12-kDa protein was confirmed to be the N-terminal kappa1 light chain fragment (variable region) consisting of residues 1-108 or 1-109 and having one disulfide bond. The 24-kDa protein was determined to be the intact kappa1 light chain containing a cysteinyl posttranslational modification at Cys214 and disulfide bonds located at Cys23-Cys88, Cys134-Cys194, and Cys214-Cys. The methods used in this report enable high-sensitivity determination of amino acid sequence and variation in intact and truncated light chains as well as posttranslational modifications. This approach facilitates consideration of the effect of cysteinylation on the native protein structure and the potential involvement of this modification in AL amyloidosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of proteins in cell-free extracts using liquid chromatography-electrospray ionization mass spectrometry.

A rapid method for the identification and characterization of proteins in bacterial cell-free extracts has been developed using directly combined liquid chromatography-electrospray mass spectrometry. The usefulness of this technique is demonstrated for monitoring the expression and chemical modification of phosphoenolpyruvate-sugar phosphotransferase system (PTS) proteins from E. coli with mole...

متن کامل

Effects of matrix, electrospray solution, and laser light on the desorption and ionization mechanisms in electrospray-assisted laser desorption ionization mass spectrometry.

Electrospray-assisted laser desorption ionization (ELDI) is a technique which combines laser desorption with subsequent electrospray ionization. It is useful for directly detecting small and large molecules in solid or liquid samples under ambient conditions. In this paper, the detection of the protein molecules desorbed on a dry protein spot by using pulse laser energies of up to 300 microJ wa...

متن کامل

What is hemoglobin A1c? An analysis of glycated hemoglobins by electrospray ionization mass spectrometry.

Hemoglobin A1c (HbA1c) is a stable minor Hb variant formed in vivo by posttranslational modification by glucose, originally identified by using cation exchange chromatography, and containing primarily glycated N-terminal beta-chains. However, the structure(s) of the quantified species has not been elucidated, and the available methods lack a reference standard. We used electrospray ionization m...

متن کامل

Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification.

We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity ap...

متن کامل

Solvent-free mass spectrometry for hydrophobic peptide sequence analysis and protein conformation studies.

The breakthrough in soft ionization methods for biopolymers, electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) (1,2), revolutionized mass spectrometry (MS). As a result of these effective bioanalytical technologies, the entire field of proteomics changed, and the use of mass spectrometers for protein identification by accurate mass measurements or de novo seq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical biochemistry

دوره 295 1  شماره 

صفحات  -

تاریخ انتشار 2001