Differences and intersubject variability of loudness discomfort levels measured in sound pressure level and hearing level for TDH-50P and ER-3A earphones.

نویسندگان

  • M Valente
  • L G Potts
  • M Valente
چکیده

Loudness discomfort levels (LDLs) were measured in dB HL and SPL at discrete frequencies between 500 to 4000 Hz on 31 hearing-impaired ears using TDH-50P and ER-3A earphones. The results revealed no significant differences in the measured sound pressure level (SPL) between the two earphones at all test frequencies. However, with dB HL measurements, statistically significant differences were revealed at 1500 and 4000 Hz between earphone conditions. The results also revealed large intersubject differences in the measured LDL (HL and SPL) for both earphones. The results of this study highlight the difficulty in accurately predicting individual performance from averaged group data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intersubject variability of real-ear sound pressure level: conventional and insert earphones.

Measures of the sound pressure level (SPL) near the eardrum were determined at discrete frequencies between 500 and 4000 Hz on 50 ears using TDH-39P and ER-3A earphones with the attenuator of an audiometer fixed at 90 dB HL. Results revealed significant differences in the measured SPL between the two earphones at all test frequencies. Results also revealed large intersubject differences in the ...

متن کامل

Comparison of Etymotic insert and TDH supra-aural earphones in auditory brainstem response measurement.

There are few systematic comparisons of Etymotic ER-3A insert earphones versus supra-aural earphones in auditory brainstem response (ABR) measurement. We compared ER-3A insert earphones and two types of supra-aural earphones (TDH-39P and TDH-49P) in a group of normal hearing adults. Acoustic analyses revealed spectral and temporal differences among earphones. Behavioral and ABR thresholds to cl...

متن کامل

Sound Quantity and Quality of Sampo 3065 Combine Harvester

ABSTRACT- Noise is considered as one of the most debilitating conditions in farming operations. In this study, a number of factors affecting the noise generated by Sampo 3065 combine harvesters were evaluated. Factors were engine speed and gear ratio for combines with and without original cabins. A factorial experiment arranged as a completely randomized design with four replicates was used. Re...

متن کامل

Reference threshold levels for an ER-3A insert earphone.

The purpose of this study was to obtain normal hearing thresholds for an ER-3A insert earphone as a contribution for future standardization and for comparison with previous studies and interim ANSI and ISO insert earphone reference equivalent threshold sound pressure levels (RETSPLs). Hearing thresholds were obtained on each ear of 48 normal-hearing subjects from 125 to 8000 Hz using ER-3A and ...

متن کامل

Estimates of loudness, loudness discomfort, and the auditory dynamic range: normative estimates, comparison of procedures, and test-retest reliability.

The purpose of this series of experiments was to establish normative reference values for absolute and relative judgements of loudness discomfort and for the auditory dynamic range (DR), and to evaluate intersubject variability and intra-subject test-retest reliability for the respective measures of loudness discomfort. To establish the normal auditory DR, audiometric thresholds and loudness di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 1997