In Vitro Comparative Evaluation of Cleaning Efficacy and Volumetric Filling in Primary Molars: Cone Beam Computed Tomography Evaluation
نویسندگان
چکیده
INTRODUCTION Pulpectomy of primary teeth is mostly carried out with hand files and broaches which is tricky and time consuming procedure. The development of new design features like varying tapers, non-cutting safety tips and varying length of cutting blades have resulted in new generation of rotary instruments. AIM To compare and evaluate cleaning efficacy, canal preparation and volumetric filling using conventional files and rotary V Taper files through cone beam computed tomography. MATERIALS AND METHOD Thirty extracted primary molars were selected. The teeth were randomly divided into three groups each containing 10 teeth i.e. 30 canals in each group. Group A was instrumented with K files; Group B rotary V Taper files and Group C was Hybrid group. Sodium hypochlorite (1%) was used for irrigation. Root canal filling was done with Zinc Oxide Eugenol cement in all groups. The volumetric analysis i.e. Percentage of Volume (POV) of the root canal filling in primary molars was done through CBCT Software. RESULT In present study, p- value was found to be significant (<0.05). Almost 100% of canals of hybrid group were fully filled and 63.3% of canals of hand filing group were partially filled. The filling was found to be dense and no. of voids was least in hybrid group. CONCLUSION Clinical time required in primary molar endodontics, especially with unpredictability and difficulty of canal morphology, is inevitable. The study confirms superior ability of rotary-file systems to shape severely curved canals with less time and significant decrease in procedural errors like partial filling, voids and inappropriate canal preparation.
منابع مشابه
مقایسه دقت توموگرافی سهبعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماریهای سینوس پارانازال
Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...
متن کاملA comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study
Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...
متن کاملRoot Canal Transportation in Canals Joining together: Assessed by Cone-Beam Computed Tomography
Introduction: Statement of the Problem: Cleaning and shaping are regarded as the most important aspects of root canal therapy and prerequisite for the success of endodontic treatment. Apical transportations can jeopardize the outcome of treatment due to the significant decrease in the sealing ability of root filling material. The purpose of this study was to evaluate transportation in type II c...
متن کاملEvaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography
Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...
متن کاملComparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography
Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...
متن کامل