Comparison of toxin removal outcomes in online hemodiafiltration and intra-dialytic exercise in high-flux hemodialysis: A prospective randomized open-label clinical study protocol
نویسندگان
چکیده
BACKGROUND Maintenance hemodialysis (HD) patients universally suffer from excess toxin load. Hemodiafiltration (HDF) has shown its potential in better removal of small as well as large sized toxins, but its efficacy is restricted by inter-compartmental clearance. Intra-dialytic exercise on the other hand is also found to be effective for removal of toxins; the augmented removal is apparently obtained by better perfusion of skeletal muscles and decreased inter-compartmental resistance. The aim of this trial is to compare the toxin removal outcome associated with intra-dialytic exercise in HD and with post-dilution HDF. METHODS/DESIGN The main hypothesis of this study is that intra-dialytic exercise enhances toxin removal by decreasing the inter-compartmental resistance, a major impediment for toxin removal. To compare the HDF and HD with exercise, the toxin rebound for urea, creatinine, phosphate, and β2-microglobulin will be calculated after 2 hours of dialysis. Spent dialysate will also be collected to calculate the removed toxin mass. To quantify the decrease in inter-compartmental resistance, the recently developed regional blood flow model will be employed. The study will be single center, randomized, self-control, open-label prospective clinical research where 15 study subjects will undergo three dialysis protocols (a) high flux HD, (b) post-dilution HDF, (c) high flux HD with exercise. Multiple blood samples during each study session will be collected to estimate the unknown model parameters. DISCUSSION This will be the first study to investigate the exercise induced physiological change(s) responsible for enhanced toxin removal, and compare the toxin removal outcome both for small and middle sized toxins in HD with exercise and HDF. Successful completion of this clinical research will give important insights into exercise effect on factors responsible for enhanced toxin removal. The knowledge will give confidence for implementing, sustaining, and optimizing the exercise in routine dialysis care. We anticipate that toxin removal outcomes from intra-dialytic exercise session will be comparable to that obtained by standalone HDF. These results will encourage clinicians to combine HDF with intra-dialytic exercise for significantly enhanced toxin removal. TRIAL REGISTRATION ClinicalTrials.gov number, NCT01674153.
منابع مشابه
A comparison of on-line hemodiafiltration and high-flux hemodialysis: a prospective clinical study.
Some of the morbidity associated with chronic hemodialysis is thought to result from retention of large molecular weight solutes that are poorly removed by diffusion in conventional hemodialysis. Hemodiafiltration combines convective and diffusive solute removal in a single therapy. The hypothesis that hemodiafiltration provides better solute removal than high-flux hemodialysis was tested in a ...
متن کاملLong-term outcomes in online hemodiafiltration and high-flux hemodialysis: a comparative analysis.
BACKGROUND AND OBJECTIVES Theoretical advantages exist of online hemodiafiltration (HDF) over high-flux hemodialysis (HD), but outcome data are scarce. Our objective was to compare outcomes between these modalities. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS We studied 858 incident patients in our incremental high-flux HD and online HDF program during an 18-yr period. We compared outcomes,...
متن کاملParameters of Hemodialysis Adequacy and Patients' Survival Depending on Treatment Modalities.
INTRODUCTION Retrospective studies showed that hemodiafiltration was associated with a reduced risk of mortality compared with standard hemodialysis in the patients with end-stage renal disease. Recently, a few prospective randomized clinical trials found no advantage in survival with hemodiafiltration as compared with high-flux hemodialysis and low-flux hemodialysis. The aim of this study was ...
متن کاملRevisiting the Middle Molecule Hypothesis of Uremic Toxicity: A Systematic Review of Beta 2 Microglobulin Population Kinetics and Large Scale Modeling of Hemodialysis Trials In Silico.
BACKGROUND Beta-2 Microglobulin (β2M) is a prototypical "middle molecule" uremic toxin that has been associated with a higher risk of death in hemodialysis patients. A quantitative description of the relative importance of factors determining β2M concentrations among patients with impaired kidney function is currently lacking. METHODS Herein we undertook a systematic review of existing studie...
متن کاملEffect of cool vs. warm dialysate on toxin removal: rationale and study design
BACKGROUND Cool dialysate is often recommended for prevention of intra-dialytic hypotensive episodes in maintenance hemodialysis (HD) patients. However, its effect on toxin removal is not studied. It is known that inter-compartmental resistance is the main barrier for toxin removal. Cool dialysate can potentially increase this resistance by vasoconstriction and thus impair the toxin removal. Th...
متن کامل