Shear bond strengths of ceramic brackets bonded with different light-cured glass ionomer cements: an in vitro study.

نویسندگان

  • V Cacciafesta
  • U Süssenberger
  • P G Jost-Brinkmann
  • R R Miethke
چکیده

The purpose of this study was to evaluate the shear bond strengths of four light-cured glass ionomer cements used for direct bonding of ceramic brackets, and to compare the results with a two-paste chemically-cured composite resin. Two commercially available polycrystalline ceramic brackets, with either chemically or mechanically retentive bracket bases, were evaluated. The brackets were bonded to 100 freshly extracted bovine incisors, and, after storage in tap water at room temperature for 24 hours, they were subsequently tested in a shear mode using a universal testing machine. The maximum bond strength and the site of bond failure were recorded. With the mechanically retentive base, Fuji Ortho LC produced the highest bond strength (18.50 MPa), which was not significantly different from the values achieved with Concise (14.88 MPa) (P > 0.1) and Photac Bond (13.86 Mpa) (P = 0.1). The lowest bond strength was provided by locomp A20 (5.23 MPa). With the chemically retentive base, the highest bond strength was measured with Concise (29.27 MPa), which was significantly (P < 0.01) higher than the values for Photac Bond (16.27 MPa) and Fuji Ortho LC (13.48 MPa). Again locomp A20 produced the lowest bond strength (3.21 MPa). Three cements (Dyract Ortho, locomp A20 and Fuji Ortho LC) provided higher shear bond strengths with the mechanical retention system, whereas Concise and Photac Bond gave higher strengths with the silane-treated bracket bases. However, the strengths were statistically significantly different only for locomp A20 (P = 0.001) and Concise (P = 0.001). With the mechanically retentive base, Dyract Ortho and locomp A20 failed at the enamel-adhesive interface, whereas Photac Bond and Concise debonded at the bracket-adhesive interface. Fuji Ortho LC failed at both, the bracket-adhesive (40 per cent) and the adhesive-enamel (60 per cent) interface. With the chemically retentive base, all the adhesives failed at the enamel-adhesive interface. Only one bracket fracture occurred in this study, and no enamel damage was detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bond strength of orthodontic brackets using different light and self-curing cements.

The purpose of the study was to evaluate the shear bond strength of stainless steel orthodontic brackets directly bonded to extracted human premolar teeth. Fifty teeth were randomly divided into five groups: (1) System One (chemically cured composite resin), (2) Light Bond (light-cured composite resin), (3) Vivaglass Cem (self-curing glass ionomer cement), (4) Fuji Ortho LC (light-cured glass i...

متن کامل

Comparison of shear bond strength of stainless steel brackets bonded with three light- cured adhesives

Introduction: The bonding process of the brackets to enamel has been a critical issue in orthodontic research. The purpose of this study was to evaluate the shear bond strength of 3 light-cured adhesives (transbond XT, Z250, light bond). Materials &Methods: In this study sixty extracted human premolars were collected and randomly divided into 3 test groups. All teeth were etched by 37% phosp...

متن کامل

Evaluation of Shear Bond Strengths of Three Adhesive Materials Used to Retain Fiber Post in the Severely Damaged Primary Anterior Teeth

Background and Objective: Tooth decay and periodontal problems are among the most common human diseases which are considered unsolved health problems in most countries of the world. This study aimed to investigate and compare the shear bond strength of the fiber post with three different types of cement, including Glass ionomer, as well as Universal and Flowable composites. Materials and Metho...

متن کامل

Comparison of shear bond strength of the stainless steel metallic brackets bonded by three bonding systems

Introduction: In orthodontic treatment, it is essential to establish a satisfactory bond between enamel and bracket. After the self-etch primers (SEPs) were introduced for the facilitation of bracket bonding in comparison to the conventional etch-and-bond system, multiple studies have been carried out on their shear bond strengths which have yielded different results. This study was aimed at co...

متن کامل

Shear Bond Strength of Orthodontic Brackets Bonded with Glass Ionomer Cement

Introduction A great number of techniques have been used for bonding orthodontic brackets to the tooth surfaces. Glass ionomer cements are frequently used material for this purpose. The aim of this study was to measure the shear bond strength of orthodontic brackets bonded with glass ionomer cement Ortho Fuji LC and remained adhesive on the enamel surface after brackets debonding. Material and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 1998