Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence

نویسندگان

  • Art Sedrakyan
  • Sharon-Lise T Normand
  • Stefan Dabic
  • Samantha Jacobs
  • Stephen Graves
  • Danica Marinac-Dabic
چکیده

OBJECTIVE To determine comparative safety and effectiveness of combinations of bearing surfaces of hip implants. DESIGN Systematic review of clinical trials, observational studies, and registries. DATA SOURCES Medline, Embase, Cochrane Controlled Trials Register, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the United States Food and Drug Administration. STUDY SELECTION Criteria for inclusion were comparative studies in adults reporting information for various combinations of bearings (such as metal on metal and ceramic on ceramic). Data search, abstraction, and analyses were independently performed and confirmed by at least two authors. Qualitative data syntheses were performed. RESULTS There were 3139 patients and 3404 hips enrolled in 18 comparative studies and over 830 000 operations in national registries. The mean age range in the trials was 42-71, and 26-88% were women. Disease specific functional outcomes and general quality of life scores were no different or they favoured patients receiving metal on polyethylene rather than metal on metal in the trials. While one clinical study reported fewer dislocations associated with metal on metal implants, in the three largest national registries there was evidence of higher rates of implant revision associated with metal on metal implants compared with metal on polyethylene. One trial reported fewer revisions with ceramic on ceramic compared with metal on polyethylene implants, but data from national registries did not support this finding. CONCLUSIONS There is limited evidence regarding comparative effectiveness of various hip implant bearings. Results do not indicate any advantage for metal on metal or ceramic on ceramic implants compared with traditional metal on polyethylene or ceramic on polyethylene bearings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Appraisal of evidence base for introduction of new implants in hip and knee replacement: a systematic review of five widely used device technologies

OBJECTIVE To determine the evidence of effectiveness and safety for introduction of five recent and ostensibly high value implantable devices in major joint replacement to illustrate the need for change and inform guidance on evidence based introduction of new implants into healthcare. DESIGN Systematic review of clinical trials, comparative observational studies, and registries for comparati...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

The choice between hip prosthetic bearing surfaces in total hip replacement: a protocol for a systematic review and network meta-analysis

BACKGROUND Prosthetic hip implants have many combinations of bearing surface materials, sizes, and fixation techniques, which can determine the quality of life of patients after primary total hip replacement (THR) and the likelihood of needing revision surgery. When an implant fails, patients require revision THR, which is distressing to the patient and expensive for the health care payer. Prim...

متن کامل

A critical appraisal of the evidence regarding the choice of common bearing couples available for total hip arthroplasty.

There are a variety of materials used in bearing components in total hip replacement (THR). Metal-on-polyethylene replacements, having undergone small technical refinements in design over the last 30- 40 years, give, according to the Scandinavian hip register, very good 10-year outcomes. However, aseptic loosening, caused to a great extent by adverse biological local reactions, induced by wear ...

متن کامل

Some Notes on Critical Appraisal of Prevalence Studies; Comment on: “The Development of a Critical Appraisal Tool for Use in Systematic Reviews Addressing Questions of Prevalence”

Decisions in healthcare should be based on information obtained according to the principles of Evidence-Based Medicine (EBM). An increasing number of systematic reviews are published which summarize the results of prevalence studies. Interpretation of the results of these reviews should be accompanied by an appraisal of the methodological quality of the included data and studies. The critical a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 343  شماره 

صفحات  -

تاریخ انتشار 2011