Bridging Plate Development for Treatment of Segmental Bone Defects of the Canine Mandible: Mechanical Tests and Finite Element Method.

نویسندگان

  • Elisângela Perez de Freitas
  • Sheila Canevese Rahal
  • Antonio Carlos Shimano
  • Jorge Vicente Lopes da Silva
  • Pedro Yoshito Noritomi
  • Alexander Oliveira El-Warrak
  • Alessandra Melchert
چکیده

With regard to the canine mandible, a mistaken concept of application is to assume that systemic plate-bone resistance is provided by the implant so that biomechanical position could be ignored. Because the alveolar border of the mandible is a tensile zone, the plate would ideally be positioned near this area while avoiding important structures. The aim of this study was to develop 2 bridging plates for the treatment of a segmental bone defect of the canine mandible using monocortical screws to avoid damage to the tooth roots and remaining neurovascular structures. Computed tomography images of the heads of 4 dogs (rottweiler, Doberman, boxer, and miniature poodle breeds) were used as models to develop the project. The images were reconstructed in 3-dimensional (3D) format. For each dog breed, 6 mandible prototypes were produced, each with a segmental bone defect in the right mandible. The mandibular reconstruction was performed with pure titanium bridging plate and locking screws. One plate model was developed for medium- and large-breed dogs and another for small-breed dogs. Mechanical testing showed the platemandible system resists the bite forces in all dog breeds. All safety factors were greater than I in the platemandible system for medium- and large-breed dogs and greater than 10 in the plate-mandible system for small-breed dogs. Thus, bridging plates designed with differentiated geometry and monocortical locking screws showed mechanical resistance to support simulated induced bone model defects and were able to support at least 5 times the value of bite force for each evaluated dog.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of complications after reconstruction of bone defects involving complete mandibular resection using finite element modelling.

BACKGROUND In a retrospective study, risk factors for complications after the bridging of mandibular defects using reconstruction plates were reviewed. Especially the loosening of the plate-screw-mandible complex should be analyzed with a finite element model in order to reduce plate complications in future. PATIENTS AND METHODS We examined 60 patients who underwent a treatment with reconstru...

متن کامل

An investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests

The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...

متن کامل

Mechanical Buckling Analysis of Composite Annular Sector Plate with Bean-Shaped Cut-Out using Three Dimensional Finite Element Method

In this paper, mechanical buckling analysis of composite annular sector plates with bean shape cut out is studied. Composite material sector plate made of Glass-Epoxy and Graphite-Epoxy with eight layers with same thickness but different fiber angles for each layer. Mechanical loading to form of uniform pressure loading in radial, environmental and biaxial directions is assumed. The method used...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Development of a Predictive Finite Element Model For Investigation of Phases Behavior After Cold Rolling Process

 One of the surface defects that arise in sheet metal working is when the part removes from the die. Since there are no external forces to make this defect, the origin of such fail is known as residual stress. Residual stress can develop in sheet metal forming due to non uniform deformation. In this paper, the workpiece is carbon steel with different volume fractions and arrangement of ferrite ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of veterinary dentistry

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2016