Bone tissue response to an oily calcium hydroxide suspension in tibial defects. An experimental pilot study in minipigs.

نویسندگان

  • I Mihatovic
  • M Payer
  • M Bertrams
  • D Vasiliu
  • F Schwarz
  • J Becker
  • S I Stratul
چکیده

OBJECTIVES The present study was conducted to evaluate the bone tissue response after the application of an oily calcium hydroxide suspension (OCHS) into defects created in the tibial bone of minipigs. MATERIALS AND METHODS Standardized defects (2 ccm) were created into the tibia of 4 Goettinger minipigs. Defects in the test group (n = 4) were filled with OCHS (Osteora, DFS-Diamon, Riedenburg, Germany). Defects in the control group (n = 4) were filled with venous blood. Animals were sacrificed after healing periods of 4 and 8 weeks. Tibias were dissected, soft tissues removed and processed for histological analysis. Digital images (×200) were evaluated using the software CellD (Soft Imaging System, Münster, Germany). The following histomorphometrical landmarks were identified: defect size, mineralized tissue, non-mineralized tissue and residual OCHS. RESULTS Healing was uneventful in all four animals. In the test group, new bone formation was observed in the vicinity of the defect margins whereas the centre of the defect was dominated by non-mineralized tissue. Mean percentages of mineralized tissue after 4 weeks were 23.01% in the test group vs. 43.45% in the control group. The mean value for residual OCHS was 7,11% at 4 weeks. After 8 weeks mean percentages of mineralized tissue were 28.15% in the test group vs. 44.39% in the control group as well as 7.05% for residual OCHS. CONCLUSION Within the limits of the present pilot study it can be concluded that OCHS did not have a beneficial effect on new bone formation. To prove an osteoinductive potential of OCHS further studies based on a higher number of samples are needed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

12-Months Clinical Comparison between Osteoinductal® and Emdogain® for the Treatment of Intrabony Defects

Results of basic research, animal experiments as clinical studies have suggested the influence of an oily Calcium Hydroxide suspension on bone regeneration in closed defects. Its osteostimulative effect, which can be characterized as biologic, seems to rely on factors as the deposit action of the Calcium Hydroxide (sustaining the bone metabolism in a constant, long-lasting mild alkalic environm...

متن کامل

Effect of an oily calcium hydroxide suspension (Osteoinductal) on human periodontal fibroblasts. An in vitro study.

The efficacy of an oily calcium hydroxide suspension (Osteoinductal) as an adjunct to periodontal regenerative therapy has been demonstrated in recent clinical and histological studies. However, little is known about the molecular mechanisms in vitro, particularly, about the effect of oily calcium hydroxide paste on periodontal ligament (PDL) cells. Therefore the aim of the present study was to...

متن کامل

The Impact of Calcium Hydroxide on the Osteoinductive Capacity of Demineralized Freeze-Dried Bone Allograft: an In-Vitro Study

Statement of the Problem A great challenge in periodontal therapy is the regeneration enhancement of osseous defects through applying osteoinductive materials. Demineralized freeze-dried bone allograft (DFDBA) has already been introduced as an allograft with osteoconductive and variable osteoinductive properties. Calcium hydroxide [Ca(OH)2] is an available well-known material in dentistry, whic...

متن کامل

Radiographic comparison of the repaired bone in maxillary alveolar cleft of dog by tissue engineering and autogenous bone grafting techniques

BACKGROUND: Dental disease, trauma and maxillofacial surgeries can cause alveolar bone defects. Among different kinds of treatment, autogenous bone grafts is accepted as a golden standard. On the other hand, because of limitation of treatment with autogenous bone grafts, osteogenic cells derived from stem cells are suggested. OBJECTIVES: The aim of this study was to compare the mean density of ...

متن کامل

Histomorphometric Analysis of Newly-formed Bone Using Octacalcium Phosphate and Bone Matrix Gelatin in Rat Tibial Defects

Background: Repair of bone defects is challenging for reconstructive and orthopedic surgeons. In this study, we aimedto histomorphometrically assess new bone formation in tibial bone defects filled with octacalcium phosphate (OCP),bone matrix gelatin (BMG), and a combination of both.Methods: A total of 96 male Sprague Dawley rats aged 6-8 weeks weighing 120-150 g were randomly allocatedinto thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery

دوره 42 7  شماره 

صفحات  -

تاریخ انتشار 2014