Optimal stimulation settings for CMAP scan registrations
نویسندگان
چکیده
BACKGROUND The CMAP (Compound Muscle Action Potential) scan is a non-invasive electrodiagnostic tool, which provides a quick and visual assessment of motor unit potentials as electrophysiological components that together constitute the CMAP. The CMAP scan records the electrical activity of the muscle (CMAP) in response to transcutaneous stimulation of the motor nerve with gradual changes in stimulus intensity. Large MUs, including those that result from collateral reinnervation, appear in the CMAP scan as so-called steps, i.e., clearly visible jumps in CMAP amplitude. The CMAP scan also provides information on nerve excitability. This study aims to evaluate the influence of the stimulation protocol used on the CMAP scan and its quantification. METHODS The stimulus frequency (1, 2 and 3 Hz), duration (0.05, 0.1 and 0.3 ms), or number (300, 500 and 1000 stimuli) in CMAP scans of 23 subjects was systematically varied while the other two parameters were kept constant. Pain was measured by means of a visual analogue scale (VAS). Non-parametric paired tests were used to assess significant differences in excitability and step variables and VAS scores between the different stimulus parameter settings. RESULTS We found no effect of stimulus frequency on CMAP scan variables or VAS scores. Stimulus duration affected excitability variables significantly, with higher stimulus intensity values for shorter stimulus durations. Step variables showed a clear trend towards increasing values with decreasing stimulus number. CONCLUSIONS A protocol delivering 500 stimuli at a frequency of 2 Hz with a 0.1 ms pulse duration optimized CMAP scan quantification with a minimum of subject discomfort, artefact and duration of the recording. CMAP scan variables were influenced by stimulus duration and number; hence, these need to be standardized in future studies.
منابع مشابه
Motor amplitude of median nerve with stimulation in the palm a reliable indicator for axonal loss in carpal tunnel syndrome
Background and Aim: The present study aimed to use the median nerve compound muscle action potential (CMAP) amplitude by stimulation at the palm instead of abductor pollicis brevis (APB) needle electromyography (EMG) for determining a sign of axonal loss in patients with carpal tunnel syndrome (CTS). Methods and Materials/Patients: This study was performed on 180 patients with CTS referred to ...
متن کاملEvaluation of Motor Neuron Excitability by CMAP Scanning with Electric Modulated Current
Introduction. Compound Muscle Action Potential (CMAP) scan is a noninvasive promissory technique for neurodegenerative pathologies diagnosis. In this work new CMAP scan protocols were implemented to study the influence of electrical pulse waveform on peripheral nerve excitability. Methods. A total of 13 healthy subjects were tested. Stimulation was performed with an increasing intensities range...
متن کاملهمبستگی بین دامنه CMAP عضله بازکننده کوتاه انگشتان پا در پی تحریک عصب پرونئال و شاخص HbA1C در مبتلایان به دیابت نوع 2
Background and Objective: Diabetic peripheral neuropathy (DPN) is a common sequela of diabetes. Late diagnosis of DPN may result in ulcer and amputation of the lower limbs. Electrodiagnostic (EDX) testing is the golden standard for DPN assessment. However, due to the limitations of EDX testing, the estimation of EDX indices using a regression model is of utmost importance. Herein, we sought to ...
متن کاملDiaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation.
The purpose of the study was to compare electrical stimulation (ES) and cervical magnetic stimulation (CMS) of the phrenic nerves for the measurement of the diaphragm compound muscle action potential (CMAP) and phrenic nerve conduction time. A specially designed esophageal catheter with three pairs of electrodes was used, with control of electrode positioning in 10 normal subjects. Pair A and p...
متن کاملEstimating motor unit numbers from a CMAP scan.
INTRODUCTION Compound muscle action potential (CMAP) scans are detailed stimulus-response curves which provide information about motor unit properties in neuromuscular disorders. This study assessed a method of automatic motor unit number estimation (MUNE) from 5-min CMAP scans. METHODS A preliminary model, derived from the variance and slope of the scan, is refined to fit the CMAP scan more ...
متن کامل