Surgeons' Exposure to Radiation in Single- and Multi-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion; A Prospective Study

نویسندگان

  • Haruki Funao
  • Ken Ishii
  • Suketaka Momoshima
  • Akio Iwanami
  • Naobumi Hosogane
  • Kota Watanabe
  • Masaya Nakamura
  • Yoshiaki Toyama
  • Morio Matsumoto
چکیده

Although minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has widely been developed in patients with lumbar diseases, surgeons risk exposure to fluoroscopic radiation. However, to date, there is no studies quantifying the effective dose during MIS-TLIF procedure, and the radiation dose distribution is still unclear. In this study, the surgeons' radiation doses at 5 places on the bodies were measured and the effective doses were assessed during 31 consecutive 1- to 3-level MIS-TLIF surgeries. The operating surgeon, assisting surgeon, and radiological technologist wore thermoluminescent dosimeter on the unshielded thyroid, chest, genitals, right middle finger, and on the chest beneath a lead apron. The doses at the lens and the effective doses were also calculated. Mean fluoroscopy times were 38.7, 53.1, and 58.5 seconds for 1, 2, or 3 fusion levels, respectively. The operating surgeon's mean exposures at the lens, thyroid, chest, genitals, finger, and the chest beneath the shield, respectively, were 0.07, 0.07, 0.09, 0.14, 0.32, and 0.05 mSv in 1-level MIS-TLIF; 0.07, 0.08, 0.09, 0.18, 0.34, and 0.05 mSv in 2-level; 0.08, 0.09, 0.14, 0.15, 0.36, and 0.06 mSv in 3-level; and 0.07, 0.08, 0.10, 0.15, 0.33, and 0.05 mSv in all cases. Mean dose at the operating surgeon's right finger was significantly higher than other measurements parts (P<0.001). The operating surgeon's effective doses (0.06, 0.06, and 0.07 mSv for 1, 2, and 3 fusion levels) were low, and didn't differ significantly from those of the assisting surgeon or radiological technologist. Revision MIS-TLIF was not associated with higher surgeons' radiation doses compared to primary MIS-TLIF. There were significantly higher surgeons' radiation doses in over-weight than in normal-weight patients. The surgeons' radiation exposure during MIS-TLIF was within the safe level by the International Commission on Radiological Protection's guidelines. The accumulated radiation exposure, especially to surgeon's hands, should be carefully monitored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MLIF - Minimally Invasive Lumbar Interbody Fusion MTLIF - Minimally Transforaminal Lumbar Interbody Fusion ODI - Oswestry Disability Index PLIF - Posterior Lumbar Interbody Fusion TLIF - Transforaminal Lumbar Interbody Fusion VAS - Visual Analog Scale

A prospective multicentral observational study of minimally invasive fusion to treat degenerative lumbar disorders, and to report outcomes of one or two level minimally invasive posterior lumbar interbody fusion (MLIF) for degenerative lumbar disorders in a multi-center 1-year prospective study. We prospectively studied a group of 32 patients, mostly female 24 (75% female), and 8 males (25%). T...

متن کامل

Minimally Invasive Transforaminal Lumbar Interbody Fusion – An Overview of its Benefits and Pitfalls

Minimally invasive spine surgery has been on the rise in the last decade, providing the auditorium of spine surgeons with state of the art solutions to common clinical situations. Avoiding extensive soft tissue injury in miniopen Transforaminal lumbar interbody fusion (TLIF) resulted in measurable clinical benefits like decrease of blood loss, less pain and faster rehabilitation postoperatively...

متن کامل

The Clinical and Radiological Outcomes of Minimally Invasive Transforaminal Lumbar Interbody Single Level Fusion

STUDY DESIGN This is a retrospective study that was done according to clinical and radiological evaluation. PURPOSE We analyzed the clinical and radiological outcomes of minimally invasive transforaminal lumbar interbody single level fusion. OVERVIEW OF LITERATURE Minimally invasive transforaminal lumbar interbody fusion is effective surgical method for treating degenerative lumbar disease....

متن کامل

Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion.

OBJECT Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular procedure. The technique involves use of fluoroscopy to assist with pedicle screw (PS) placement. The potential exists for both the surgeon and the patient to become exposed to significant amounts of radiation. The authors undertook this study to quantify the radiation dose to the surgeon and pati...

متن کامل

Role of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review

Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014