Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

نویسندگان

  • Youngok Lee
  • Gun-Jik Kim
  • Young Eun Kim
  • Seong Wook Hong
  • Jong Tae Lee
چکیده

The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular stent-grafting for diseases of the descending thoracic aorta.

PRINCIPLES Endoluminal stent-grafts are emerging as a less invasive alternative to conventional open surgery in the management of descending thoracic aortic dissections and aneurysms. We describe our experience with endovascular stent-grafting in the treatment of thoracic aorta pathology. METHODS 17 Patients were treated with 23 endovascular stents. The underlying pathology was an atheroscler...

متن کامل

Efficacy of contrast-enhanced ultrasonography in detecting graft rupture sites after abdominal aortic aneurysm repair.

Non-anastomotic graft rupture is a rare but critical complication after abdominal aortic aneurysm (AAA) repair. Therefore, identifying the rupture sites is important to perform endovascular stent grafting. A 78-year old man who had undergone Y-grafting for infrarenal AAA before 17 years was referred to our hospital with the complaints of abdominal pain. Computed tomography revealed acute pancre...

متن کامل

Simultaneous abdominal aortic replacement and thoracic stent-graft placement for multilevel aortic disease.

PURPOSE Patients with aneurysmal disease involving both the descending thoracic and abdominal aorta have historically required simultaneous or sequential conventional operations, but the morbidity rate is high with either approach in these patients, who often exhibit coexisting cardiopulmonary disease. Transluminally placed endovascular grafts have recently been developed for repair of aortic a...

متن کامل

Patent Extra-Anatomic Graft 12 Years after Ascending-Descending Aortic Bypass for Interpositional Graft Infection

A male car driver who sustained polytrauma in a road traffic accident when he was 25 years old, had emergency partial hepatectomy performed for liver laceration, followed by interpositional graft (18 mm woven Dacron) repair for transection of the proximal descending aorta via a left thoracotomy. He also had multiple fractures which were treated conservatively. His postoperative recovery was com...

متن کامل

Aneurysm growth after late conversion of thoracic endovascular aortic repair

A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four seq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2016