Resting energy expenditure measured longitudinally following hip fracture compared to predictive equations: is an injury adjustment required?
نویسندگان
چکیده
The present study measuring resting energy expenditure (REE; kJ/d) longitudinally using indirect calorimetry in six elderly women aged > or =70 years following surgery for hip fracture, describes changes over time (days 10, 42 and 84 post-injury) and compares measured values to those calculated from routinely applied predictive equations. REE was compared to REE predicted using the Harris Benedict and Schofield equations, with and without accounting for the theoretical increase in energy expenditure of 35 % secondary to physiological stress of injury and surgery. Mean (95 % CI) measured REE (kJ/d) was 4704 (4354, 5054), 4090 (3719, 4461) and 4145 (3908, 4382) for days 10, 42 and 84, respectively. A time effect was observed for measured REE, P=0.003. Without adjusting for stress the mean difference and 95 % limits of agreement for measured and predicted REE (kJ/kg per d) for the Harris Benedict equation were 1 (-9, 12), 10 (2, 18) and 9 (1, 17) for days 10, 42 and 84, respectively. The mean difference and 95 % limits of agreement for measured and predicted REE (kJ/kg per d) for the Schofield equation without adjusting for stress were 8 (-3, 19), 16 (6, 26) and 16 (10, 22) for days 10, 42 and 84, respectively. After adjusting for stress, REE predicted from the Harris Benedict or Schofield equations overestimated measured REE by between 38 and 69 %. Energy expenditure following fracture is poorly understood. Our data suggest REE was relatively elevated early in recovery but declined during the first 6 weeks. Using the Harris Benedict or Schofield equations adjusted for stress may lead to overestimation of REE in the clinical setting. Further work is required to evaluate total energy expenditure before recommendations can be made to alter current practice for calculating theoretical total energy requirements of hip fracture patients.
منابع مشابه
Determination of resting energy expenditure after severe burn.
The purpose of this study was to evaluate the accuracy of nine predictive equations for calculating energy expenditure in severely burned adult subjects. The selected equations have been reported as commonly used or determined to be the most accurate. This prospective, observational study was conducted on adult subjects admitted between October 2007 and July 2010 with ≥ 20% TBSA full-thickness ...
متن کاملThe agreement between measured and predicted resting energy expenditure in patients with pancreatic cancer: a pilot study.
OBJECTIVE To compare measured resting energy expenditure to resting energy expenditure predicted from eight published prediction equations in a sample of patients with pancreatic cancer. DESIGN Cross-sectional study. SETTING Ambulatory patients of a tertiary private hospital. PARTICIPANTS Eight patients with pancreatic cancer (5 males, 3 females; age: 62.0+/- 5.2 years; BMI: 24.4+/- 3.2 k...
متن کاملValidation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients.
OBJECTIVE Use comparison with indirect calorimetry to confirm the ability of our previously described equation to predict resting energy expenditure in mechanically ventilated patients. DESIGN Prospective, validation study. SETTING Eighteen-bed, medical intensive care unit at a teaching hospital. PATIENTS All adult patients intubated >24 hrs were assessed for eligibility. Exclusion criter...
متن کاملPredictive equations over-estimate the resting energy expenditure in amyotrophic lateral sclerosis patients who are dependent on invasive ventilation support
BACKGROUND Amyotrophic lateral sclerosis (ALS) is a form of degenerative motor neuron disease. At the end stage of the disease artificial feeding is often required. Nevertheless, very little is known about the energy demand of those ALS patients who are chronically dependent on tracheostomy intermittent positive pressure ventilation. The objective of our study was to clarify the resting energy ...
متن کاملValidity of the BodyGem calorimeter and prediction equations for the assessment of resting energy expenditure in overweight and obese Saudi males.
OBJECTIVE To assess the accuracy of resting energy expenditure (REE) measurement in a sample of overweight and obese Saudi males, using the BodyGem device (BG) with whole room calorimetry (WRC) as a reference, and to evaluate the accuracy of predictive equations. METHODS Thirty-eight subjects (mean +/- SD, age 26.8+/- 3.7 years, body mass index 31.0+/- 4.8) were recruited during the period fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of nutrition
دوره 94 6 شماره
صفحات -
تاریخ انتشار 2005