Intra- and inter-rater reliability of maximum inspiratory pressure measured using a portable capsule-sensing pressure gauge device in healthy adults

نویسندگان

  • Nikita S Jalan
  • Sonam S Daftari
  • Seemi S Retharekar
  • Savita A Rairikar
  • Ashok M Shyam
  • Parag K Sancheti
چکیده

BACKGROUND Measurement of maximum inspiratory pressure is the most prevalent method used in clinical practice to assess the strength of the inspiratory muscles. Although there are many devices available for the assessment of inspiratory muscle strength, there is a dearth of literature describing the reliability of devices that can be used in clinical patient assessment. The capsule-sensing pressure gauge (CSPG-V) is a new tool that measures the strength of inspiratory muscles; it is easy to use, noninvasive, inexpensive and lightweight. OBJECTIVE To test the intra- and inter-rater reliability of a CSPG-V device in healthy adults. METHODS A cross-sectional study involving 80 adult subjects with a mean (± SD) age of 22±3 years was performed. Using simple randomization, 40 individuals (20 male, 20 female) were used for intrarater and 40 (20 male, 20 female) were used for inter-rater reliability testing of the CSPG-V device. The subjects performed three inspiratory efforts, which were sustained for at least 3 s; the best of the three readings was used for intra- and inter-rater comparison. The intra- and inter-rater reliability were calculated using intraclass correlation coefficients (ICCs). RESULTS The intrarater reliability ICC was 0.962 and the inter-rater reliability ICC was 0.922. CONCLUSION Results of the present study suggest that maximum inspiratory pressure measured using a CSPG-V device has excellent intraand inter-rater reliability, and can be used as a diagnostic and prognostic tool in patients with respiratory muscle impairment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of an Electronic Inspiratory Loading Device for Assessing Pulmonary Function in Post-Stroke Patients

BACKGROUND The purpose of this study was to examine the inter- and intra-rater reliability of an electronic inspiratory loading device for the assessment of pulmonary functions: maximum inspiratory pressure, peak inspiratory flow, and vital capacity. MATERIAL/METHODS Subjects were 50 patient volunteers in a rehabilitation hospital who had experienced their first episode of unilateral stroke w...

متن کامل

The intra-rater reliability of the measurement of the center of pressure sway in young women with dorsal hyper kyphosis and young healthy women in standing position: a pilot study

Background: Posturography is a method in which the postural stability of adults is evaluated by measuring the center of pressure sway. This study aims to evaluate the reproducibility of measuring the center of pressure oscillation in standing position with internal perturbation in healthy young women with and without hyperkyphosis. Methods: Ten women with dorsal hyperkyphosis with the mean age...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

Evaluation of Spasticity Using the Ashworth Scale with Intermediate Scores (ASIS)

Objectives: The main purpose of this research was to study and contribute to an accurate test of spastic limb. The intra, inter rater reliability of the test was examined. Methods: The present study was carried out in two parts In the first part of the study, the modified Ashworth Scale with Intermediate Scores (ASIS) was studied. During the second part of the study the intra, inter rater re...

متن کامل

Reliability of Semmes-Weinstein Monofilaments and Tuning Fork on Pressure and Vibration Sensation Measurements in Diabetic Patients

Objectives: Sensory neuropathy is the major cause of ulceration in diabetic patients. Periodical sensory examination is an appropriate method to detect neuropathy and decrease the risk of diabetic foot ulcer. Semmes–Weinstein Monofilaments (SWM) and tuning fork on/off test are widely used to assess pressure and vibration sensitivity. The present study evaluated the inter- and intra-rater reliab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2015